Function
Code
Parameter
Name
Setting Range
Default
Property
P5.20
Fl curve 2
maximum input
P5.18 ~ +10.00V
10.00V
☆
P5.21
Corresponding
setting of Fl curve
2 maximum input
-100.0% ~ +100.0%
100.0%
☆
P5.22
Fl curve 2 filter
time
0.00s ~ 10.00s
0.10s
☆
P5.23
Fl curve 3
minimum input
-10.00V ~ P5.25
-10.00V
☆
P5.24
Corresponding
setting of Fl curve
3 minimum input
-100.0% ~ +100.0%
-100.0%
☆
P5.25
Fl curve 3
maximum input
P5.23 ~ +10.00V
10.00V
☆
P5.26
Corresponding
setting of Fl curve
3 maximum input
-100 .0% ~ +100.0%
100.0%
☆
P5.27
Fl curve 3 filter
time
0.00s ~ 10.00s
0.10s
☆
P5.28
PULSE minimum
input
0.00kHz ~ P5.30
0.00kHz
☆
P5.29
Corresponding
setting of pulse
minimum input
-100.0% ~ 100.0%
0.0%
☆
P5.30
PULSE
maximum input
P5.28 ~ 100.00kHz
50.00kHz
☆
P5.31
Corresponding
setting of pulse
maximum input
-100.0% ~ 100.0%
100.0%
☆
P5.32
PULSE filter time 0.00s ~ 10.00s
0.10s
☆
P5.33
Fl curve selection
Unit's digit: FIV curve selection
1: Curve 1 (2 points, see P5.13 ~ P5.16)
2: Curve 2 (2 points, see P5.18 ~ P5.21)
3: Curve 3 (2 points, see
P5.23 ~ P5.26)
4:Curve 4 (4 points, see C6.00 ~ C6.07)
5:Curve 5 (4 points, see C6.08 ~ C6.15)
Ten's digit: FIC curve selection (1~5,same as FIV)
Hundred's digit: FIA curve selection(1 ~ 5,same as FIV)
321
☆
P5.34
Setting for Fl less
than minimum
input
Unit's digit: Setting for FIV less than minimum input
0:Minimum value
1:0.0%
Ten's digit: Setting for FIC less than minimum input (0~1,same as FIV)
Hundred's digit: Setting for FIA less than minimum
input(0 ~ 1,same as FIV)
000
☆
P5.35
FWD delay time 0.0s ~ 3600s
0.0s
★
P5.36
REV delay time 0.0s ~ 3600s
0.0s
★