107
Elmark Automatyka S.A.
ul. Niemcewicza 76, 05-075 Warszawa, tel. (+48) 22 773 79 37; [email protected]; www.elmark.com.pl
NIP: 5252072585; KRS: 0000803828, Sąd Rejonowy dla M-St. Warszawy, XIV Wydział Gosp. KRS; Kapitał Zakładowy 525.000 zł, w pełni opłacony
Function
Code
Parameter
Name
Setting Range
Default
Property
P7.05
LED display stop
parameters
0000-FFFF
Bit00: Set frequency (Hz)
Bit01: Bus voltage (V)
Bit02: S input status
Bit03: M01 output status
Bit04: FIV voltage M
Bit05: FIC voltage M
Bit06: Reserved
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID setting
Bit12: Pulse setting frequency(kHz)
Bit13: PID feedback value
33
☆
P7.06
Load speed display
coefficient
0.0001 ~ 6.5000
1.0000
☆
P7.07
Heatsink
temperature of
inverter
0.0⁰C ~ 150.0⁰C
-
•
P7.08
Temporary
software version
0.0⁰C ~ 150.0⁰C
-
•
P7.09
Accumulative
running time
0h ~ 65535h
-
•
P7.10
reserved
-
-
P7.11
Software
version
-
.
•
P7.12
Numbers of
decimal places for
load speed display
0: 0 decimal place
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
1
☆
P7.13
Accumulative
power-on time
0h ~ 65535h
.
•
P7.14
Accumulative
Power
consumption
0kW ~ 65535kWh
-
•
Group P8: Auxiliary Functions
P8.00
JOG running
frequency
0.00Hz ~ maximum frequency
2.00Hz
☆
P8.01
JOG acceleration
time
0.0s ~ 6500.0s
20.0s
☆
P8.02
JOG deceleration
time
0.0s ~ 6500.0s
20.0s
☆
P8.03 Acceleration time2 0.0s ~ 6500.0s
Model
dependent
☆
P8.04
Deceleration
time2
0.0s ~ 6500.0s
Model
dependent
☆
P8.05
Acceleration
time3
0.0s ~ 6500.0s
Model
dependent
☆
Summary of Contents for elmatic ED2000