99
Elmark Automatyka S.A.
ul. Niemcewicza 76, 05-075 Warszawa, tel. (+48) 22 773 79 37; [email protected]; www.elmark.com.pl
NIP: 5252072585; KRS: 0000803828, Sąd Rejonowy dla M-St. Warszawy, XIV Wydział Gosp. KRS; Kapitał Zakładowy 525.000 zł, w pełni opłacony
Function
Code
Parameter
Name
Setting Range
Default
Property
P2.10
No-load current
(synchronous
motor)
0.01A ~ P2.03
Model
dependent
★
P2.11-P2.36 Reserved
P2.37
Auto-tuning
selection
0:No auto-tuning
1:Asynchronous motor static auto-tuning
2:Asynchronous motor complete auto-tuning
0
★
Group P3: Vector Control Parameters
P3.00
Speed loop
proportional gain
1 ~ 100
30
☆
P3.01
Speed loop
integral time 1
0.01s ~ 10.00s
0.50s
☆
P3.02
Switchover
frequency 1
0.00 ~ P3.05
5.00Hz
☆
P3.03
Speed loop
proportional
gain2
1 ~ 100
20
☆
P3.04
Speed loop
integral time 2
0.01s ~ 10.00s
1.00s
☆
P3.05
Switchover
frequency 2
P3.02 ~ maximum output
frequency
10.00Hz
☆
P3.06
Vector control slip
gain
50%-200%
100%
☆
P3.07
Time constant of
speed loop filter
0.000s-0.100s
0.000s
☆
P3.08
Vector control
over-excitation
gain
0-200
64
☆
P3.09
Torque upper limit
source in speed
control mode
0: P3.10
1: FIV
2: FIC
3: Reserved
4: Pulse setting
5: Communication setting
6: MIN(FIV,FIC)
7: MAX(FIV,FIC)
0
☆
P3.10
digital setting of
torque upper limit
in speed
control mode
0.0% ~ 200.0%
150.0%
☆
P3.13
Excitation
adjustment
proportional
gain
0 ~ 60000
2000
☆
P3.14
Excitation
adjustment
integral gain
0 ~ 60000
1300
☆
Summary of Contents for elmatic ED2000
Page 1: ......