P5.29
Corresponding setting of pulse minimum input
Default
0.0%
Setting Range
-100.00% ~100.0%
P5.30
PULSE maximum input
Default
50.00kHz
Setting Range
P5.28 ~50.00kHz
P5.31
Corresponding setting of pulse maximum input
Default
100.0%
Setting Range
-100.00% ~ 100.0%
P5.32
PULSE filter time
Default
0.10s
Setting Range
0.00s ~ 10.00s
These parameters are used to set the relationship between S3 pulse frequency input and corresponding settings. The pulses can
only be input by S3. The method of setting this function is similar to that of setting Fl curve 1 ,Refer to the descriptions of Fl curve
1.
P5.33
Fl curve selection
Default
321
Setting Range
Unit's digit
FIV curve selection
1
Curve 1 (2 points, see P5.13 ~ P5.16)
2
Curve 2 (2 points, see P5.18 ~ P5.21)
3
Curve 3 (2 points, see P5.23 ~ P5.26)
4
Curve 4 (4 points, see C6.00 ~ C6.07)
5
Curve 5 (4 points, see C6.08 ~ C6.15)
Ten's digit
FIC curve selection (1~5, same as FIV)
Hundred's digit
Reserved
The unit’s digit, ten's digit and hundred's digit of this parameter are respectively used to select the corresponding curve o
f FIV,FIC.
Any one curve of the five curves can be selected for 2 analog inputs.
Curve 1, curve 2 and curve 3 are all 2-point curves, need to set in group P5. Curve 4 and curve 5 are both 4-point curves, set in
group C6. The ED2000 provides two Fl terminals as standard.
P5.34
Setting for Fl less than minimum input
Default
000
Setting Range
Unit's digit
Setting for FIV less than minimum input
0
Minimum value
1
0.0%
Ten's digit
Setting for FIC less then minimum input (0-1,same as FIV)
Hundred's
digit
Reserved
This function code is used to determine the corresponding setting when the analog input voltage is less than the minimum value.
The unit's digit, ten's digit and hundred's digit of this function code respectively correspond to the setting for FIV,FIC and FIC.
If the value of a certain digit is selected to 0, when analog input voltage is less than the minimum input, the corresponding setting
of the minimum input (P5.14, P5.19, P5.24) is used.
If the value of a certain digit is selected to 1, when analog input voltage is less than the minimum input,the corresponding value
of this analog input is 0.0%
P5.35
FWD delay time
Default
0.0s
Setting Range
0.0s-3600.0s
P5.36
REV delay time
Default
0.0s
Setting Range
0.0s-3600.0s
P5.37
S1 delay time
Default
0.0s
Setting Range
0.0s-3600.0s