Additional table 1 :The descriptions of multi-reference
he four multi-reference terminals have 16 state combinations, corresponding to 16 reference values, as listed in the following
table 1.
K4
K3
K2
K1
Reference
Setting
Corresponding
Parameter
OFF
OFF
OFF
OFF
Reference 0
PC.00
OFF
OFF
OFF
ON
Reference 1
PC.01
OFF
OFF
ON
OFF
Reference 2
PC.02
OFF
OFF
ON
ON
Reference 3
PC.03
OFF
ON
OFF
OFF
Reference 4
PC.04
OFF
ON
OFF
ON
Reference 5
PC.05
OFF
ON
ON
OFF
Reference 6
PC.06
OFF
ON
ON
ON
Reference 7
PC.07
OFF
OFF
OFF
OFF
Reference 8
PC.08
ON
OFF
OFF
ON
Reference 9
PC.09
ON
OFF
ON
OFF
Reference 10
PC.10
ON
OFF
ON
ON
Reference 11
PC.11
ON
ON
OFF
OFF
Reference 12
PC.12
ON
ON
OFF
ON
Reference 13
PC.13
ON
ON
ON
OFF
Reference 14
PC.14
ON
ON
ON
ON
Reference 15
PC.15
If the frequency soured is multi-reference, the value 100% of PC.00 to PC.15 corresponds to the maximum frequency od P012.
Besides the multi-speed function, the multi-reference can be also used as the PID setting source or the voltage source for V/ F
separation, satisfying the requirement on switchover of different setting values.
Additional table 2:Terminal function descriptions of acceleration/ deceleration time selection
Terminal 2
Terminal 1
Acceleration/
Deceleration Time Selection
Corresponding Parameters
OFF
OFF
Acceleration/
Deceleration time 1
P0.08, P0.09
OFF
ON
Acceleration/
Deceleration time 2
P8.03, P8.04
ON
OFF
Acceleration/
Deceleration time 3
P8.05, P8.06
ON
ON
Acceleration/
Deceleration time 4
P8.07, P8.08
P5.10
X filter time
Default
0.010s
Setting Range
0.000s ~ 1.000s
It is used to set the software filter time of S terminal status. If S terminals are liable to interference and may cause malfunction,
increase the value of this parameter to enhance the antiinterference capability. However, increase of S filter time will
reduce the
response of s terminals.
P5.11
Terminal command mode
Default
0
Setting Range
0
Two-line mode 1
1
Two-line mode 2
2
Three-line mode 1
3
Three-line mode 2