Inverter fault description:
Inverter fault address
Inverter fault information
8000
0000: failure-free
0001: reserve
0002: Accelerate over currant
0003: Slow down over current
0004: Constant speed over current
0005: Accelerate over the voltage
0006: Slow down over voltage
0007: Constant speed over voltage
0008: Buffer resistance overload fault
0009: Under-voltage fault
000A: The inverter overload
000B: Motor overload
000C: reserved
000D: The output phase
000E: Module is overheating
000F: External fault
0010: Abnormal communication
0011: Abnormal contactor
0012: Current detection fault
0013: Motor tuning fault
0014: reserved
0015: Abnormal parameters, reading and writing
0016: Inverter hardware failure
0017: Motor for short circuit fault
0018: reserved
0019: reserved
001A: Running time reached
001B: reserved
001C: reserved
001D: Accumulative power-<1n time reached
001E: Load becoming 0
001F: PID feedback lost during running
0028: With-wave current limit fault
0029: Motor switchover fault during running
002A: Too large speed deviation
002B: Motor over peed
002D: Motor overheat
005A: Encoder line number setting error
005B: Don't connect the encoder
005C: Initial position fault
005E: Speed feedback error
Communication failures
Address
Fault feature description
8001
0000: failure-free
0001: Password mistake
0002: The command code error
0003: CRC Checking error
0004: Invalid address
0005: Invalid parameter
0006: correcting parameter is invalid
0007: System is locked
0008: Block is EEPROM operation
Summary of Contents for elmatic ED2000