3.2
the descriptions of the key's function
Key
Name
Description
Programming key
Entry or escape of first-level menu
Data enter key
Progressively enter menu and confirm parameters.
UP Increment Key
Progressively increase data or function codes.
DOWN Decrement Key
Progressive decrease data or function codes.
Right shift Key
In parameter setting mode, press this button to select the bit to be modified. In
other modes, cyclically displays
parameters by right shift
Run key
Start to run the inverter in keypad control mode.
Stop key/Fault reset key
In running status, restricted by F7.02, can be used to stop the inverter.
When fault alarm, can be used to reset the inverter without any
restriction.
Multifunction key
3.2.1 Indicator light descriptions
Indicator Light Name
Indicator Light Description
Hz
Frequency unit
A
Current unit
V
Voltage unit
FWD/REV
light off: forward operation. light on: reverse operation.
3.3
Operational process
3.3.1 Parameter Settings
three-level menu :
1. The function code group (first menu);
2. Function code symbols (second menu);
3. Function code set value (third menu).
Explanation: the three-level menu operation, can press PRG or ENTER to return to the secondary menu. The difference between
the two is: press ENTER to set parameters in control panel, and then return to the secondary menu, and automatically move to
the next function code; Press PRG directly to return to the secondary menu, don't store parameters, and keep staying in the
current function code. Example: change the function code P1.03 from 00.00
Hz change the sample set to 50.00 Hz.