Fault reset (RESET)
The terminal is used for fault reset function, the same as the function of RESET key on
the operation panel. Remote fault reset can be implemented by
this function.
10
RUN pause
The AC drive decelerates to stop, but the running parameters are all memorized, such
as PLC, swing frequency and PIO parameters. After this function
is disabled, the AC drive resumes its status before stopping.
11
Normally open
(NO) input
of external fault
If this terminal becomes ON, the AC drive reports EF and performs the fault protection
action. For
more details, see the description of P9.47.
12
Multi-reference terminal 1
The setting of 16 speeds or 16 other references can be implemented through
combinations of 16 states of these four terminals. Refer to table 1 for more details.
13
Multi-reference terminal 2
14
Multi-reference terminal 3
15
Multi-reference terminal 4
16
Terminal 1 for
acceleration/ deceleration
Totally four groups of acceleration/deceleration time can be selected through
combinations of two states of these two terminals.
17
Terminal 2 for
acceleration/
deceleration time selection
18
Frequency source
switchover
The terminal is used to switch and choose different frequency source. Choose function
code P0.03 setting according to the frequency source .when set two kinds of frequency
source switching as
frequency source. the terminal is used to realize switching between the two frequency
source.
19
UP and DOWN setting
clear (terminal,
operation panel)
If the frequency source is digital setting, the terminal is used to clear the modification
by using the UP/ DOWN function or the increment/decrement key on the operation
panel, returning the set frequency to
the value of P0.10.
20
Command source
switchover terminal
If the command source is set to terminal control (P0.02" 1), this terminal is used to
perform switchover between terminal control and operation panel control.
If the command source is set to communication
control (P0.02 = 2), this terminal is used to perform
switchover between communication control and operation panel control.
21
Acceleration/ Deceleration
prohibited
It enables the AC drive to maintain the current frequency output without being
affected by external
signals (except the STOP command).
22
PID pause
PID is invalid temporarily. The AC drive maintains the current frequency output without
supporting PID adjustment of frequency source.
23
PLC status reset
The terminal Is used to restore the original status
of PLC control for the AC drive when PLC control is started again after a pause.
24
Swing pause
The AC drive outputs the central frequency, and the swing frequency function pauses.
25
Counter input
This terminal is used to count pulses.
26
Counter reset
This terminal is used to clear the counter status.
27
Length count input
This terminal is used to count the length.
28
Length reset
This terminal is used to clear the length.
29
Torque control prohibited The AC drive is prohibited from torque control and enters the speed control mode.