These parameters are used to set the delay time of the AC drive when the status of the terminal changes. Currently, only FWD.REV
and S1 support the delay time function.
P5.38
S valid mode selection 1
Default
00000
Setting Range
Unit's digit
FWD valid mode
0
High level valid
1
Low level valid
Ten's digit
REV valid mode (0~1,same as FWD)
Hundred's digit
S1 valid mode (0~1,same as FWD)
Thousand's digit
S2 valid mode (0~1,same as FWD)
Ten
thousand's digit
S3 valid mode (0~1, same as FWD)
P5.39
S valid mode selection 2
Default
00000
Setting Range
Unit's digit
S4 valid mode
0
High level valid
1
Low level valid
These parameters are used to set digital input terminals' valid mode . The S terminal is valid when being connected with GND, and
invalid when being disconnected from GND. The S terminal is invalid when being connected with GND, and valid when being
disconnected from GND.
Group P6: Output Terminals
The ED2000 provides 1 multi-function analog output terminal FOV, 1 multi-function relay output terminal and a M01 terminal
(used for high-speed pulse output or open-collector switch signal output) as standard.
P6.00
M01 terminal mode
Default
1
Setting Range
1
Switch signal output
P06.01
M01 function (open-collector output terminal)
Default
0
P06.02
Relay output function (RA-RB-RC)
Default
2
These two parameters are used to select the functions of the five digital output terminals. RA-RB-RC are respectively the relays
on the control board and the extension card. The functions of the output terminals are described in the following table.
Table 4-5 Functions of output terminals
Value
Function
Description
0
No output
The terminal has no function.
1
AC drive running
When the AC drive is running and has output frequency (can be zero), the terminal
outputs ON.
2
Fault output (stop)
When the AC drive stops due to a fault, the terminal outputs ON.
3
Frequency-level detection
FDT1
output
Refer to the descriptions of P8.19 and P8.20.
4
Frequency reached
Refer to the descriptions of P8.21.
5
Zero-speed running
(no output at
stop)
If the AC drive runs with the output frequency of 0, the terminal outputs ON. If the AC
drive is in the stop state, the terminal outputs OFF.
6
Motor overload pre-warning
The AC drive judges whether the motor load exceeds the overload pre-warning
threshold before performing the protection action. If the pre-warning threshold is
exceeded, the terminal outputs ON. For motor overload parameters, see the
descriptions of
P9.00to P9.02.