100
Elmark Automatyka S.A.
ul. Niemcewicza 76, 05-075 Warszawa, tel. (+48) 22 773 79 37; [email protected]; www.elmark.com.pl
NIP: 5252072585; KRS: 0000803828, Sąd Rejonowy dla M-St. Warszawy, XIV Wydział Gosp. KRS; Kapitał Zakładowy 525.000 zł, w pełni opłacony
Function
Code
Parameter
Name
Setting Range
Default
Property
P3.15
Torque
adjustment
proportional
gain
0 ~ 60000
2000
☆
P3.16
Torque
adjustment
integral gain
0 ~ 60000
1300
☆
P3.17
Speed loop
integral property
Unit's digit: integral separation
0: Disabled
1: Enabled
0
☆
P3.18 Reserved
P3.19 Reserved
P3.20 Reserved
P3.21 Reserved
P3.22 Reserved
Group P4: V/F Control Parameters
P4.00
V/F curve setting
0: Linear V/F
1: Multi-point V/F
2: Square V/F
3: 1.2-power V/F
4: 1.4-power V/F
6: 1.6-power V/F
8: 1.B-power V/F
9: Reserved
10: V/F complete separation
11: V/F half separation
0
★
P4.01
Torque boost
0.0%: (Automatic torque boost)
0.1% ~ 30.0%
Model
dependent
☆
P4.02
Cut-off frequency
of torque boost
0.00Hz ~ maximum output frequency
50.00Hz
★
P4.03
Multi-point V/F
frequency 1 (F1)
0.00Hz ~ P4.05
0.00Hz
★
P4.04
Multi-point V/F
voltage 1 (V1)
0.0% ~ 100.0%
0.0%
★
P4.05
Multi-point V/F
frequency 2 (F2)
P4.03 ~ P4.07
0.00Hz
★
P4.06
Multi-point V/F
voltage 2 (V2)
0.0% ~ 100.0%
0.0%
★
P4.07
Multi-point V/F
frequency 3 (F3)
P4.05 ~ rated motor frequency (P1.04)
0.00Hz
★
P4.08
Multi-point V/F
voltage 3 (V3)
0.0% ~ 100.0%
0.0%
★
P4.09
V/F slip
compensation gain
0.0% ~ 200.0%
0.0%
☆
P4.10
V/F over-
excitation gain
0 ~ 200
64
☆
P4.11
V/F oscillation
suppression gain
0 ~ 100
Model
dependent
☆
Summary of Contents for elmatic ED2000