GR740-UM-DS, Nov 2017, Version 1.7
362
www.cobham.com/gaisler
GR740
30.3.8 Configuration lockdown register
Table 462.
0x20 - LOCKDOWN - Configuration lockdown register
31
24 23
16 15
8
7
0
RESERVED
PERMANENT
RESERVED
REVOCABLE
0
0
0
0
r
rw*
r
rw
31: 24
RESERVED
23: 16
Permanent lock bit mask (PERMANENT) - Bit N for register at offset 4*N, 1=locked, 0=unlocked
Bits that are set to 1 in this field can only be cleared with a full system reset.
15: 8
RESERVED
7: 0
Revocable lock bit mask (REVOCABLE) - Bit N for register at offset 4*N, 1=locked, 0=unlocked