Table 503.
0xB0 - LE3 -Latency Elapsed Time 3
31
0
LE3
0
rw
31: 0
Latency Elapsed Time Value 3 (LE3) - Latency Value (96 to 127) written by initiator.(only for target)
Table 504.
0xB4 - LE4 -Latency Elapsed Time 4
31
24 23
0
LE4
RESERVED
0
0
rw
r
31: 24
Latency Elapsed Time Value 4 (LE4) - Latency Value (128 to 135) written by initiator. (only for tar-
get)
23: 0 RESERVED
Table 505.
0x0C0 - IE - Interrupt Enable
31
20 19
18
11
10
9
8
7
6
5
4
3
2
1
0
-
NCTCE
-
SETE
EDIE3 EDIE2
EDIE1 EDIE0
DITE
DIRE
TTE
TME
TRE
SE
0
0
0
0
0
r
rw
r
rw
rw
31: 20
RESERVED
19:
Non consecutive SpaceWire Time-Code received Interrupt Enable (NCTCE)
Note: Only available in silicon revision 1.
18: 11
RESERVED
10
Set ET External Interrupt Enable (SETE)
Note: Only available in silicon revision 1.
9
External Datation Interrupt Enable 3 (EDIE3)
8
External Datation Interrupt Enable 2 (EDIE2)
7
External Datation Interrupt Enable 1 (EDIE1)
6
External Datation Interrupt Enable 0 (EDIE0)
5
Distributed Interrupt TransmittedInterrupt Enable (DITE)
4
Distributed interrupt Received Received Interrupt Enable(DIRE)
3
Time-Code Transmitted Interrupt Enable (TTE) - SpaceWire Time-Code Transmitted Interrupt
Enable (only for initiator)
2
Time Message transmit Interrupt Enable (TME) - (only for initiator)
1
Time-Code Received Interrupt Enable (TRE) - SpaceWire Time-Code Received Interrupt Enable
(only for target)
0
Sync Interrupt Enable (SE) (only for target)