GR740-UM-DS, Nov 2017, Version 1.7
200
www.cobham.com/gaisler
GR740
Table 211.
0x00000001 - RTR.PNPVER - SpaceWire Plug-and-Play - Version
31
24 23
16 15
8
7
0
MAJOR
MINOR
PATCH
RESERVED
0x01
0x02
0x00
0x00
r
r
r
r
31: 24
Major version number (MAJOR) - Constant value of 0x01.
23: 16
Minor version number (MINOR) - Constant value of 0x02
15: 8
Patch / Build number (PATCH) - Constant value of 0x00.
7: 0
RESERVED
Table 212.
0x00000002 - RTR.PNPDEVSTS - SpaceWire Plug-and-Play - Device Status
31
8
7
0
RESERVED
STATUS
0x000000
0x00
r
r
31: 8
RESERVED
7: 0
Device status (STATUS) - Constant value of 0x00.
Table 213.
0x00000003 - RTR.PNPACTLNK - SpaceWire Plug-and-Play - Active Links
31
9
8
1
0
RESERVED
ACTIVE
R
0x000
0x00
0
r
r
r
31: 13
RESERVED
12: 1
Link active (ACTIVE) - If set to 1, the port with the same number as the bit index is running. If set to 0, the port
is not running. For the SpaceWire ports (ports 1-8), the corresponding bit will be set to 1 if the link interface is in
run-state and the port is not disabled through the Port Control register (RTR.PCTRL.DI = 0). For the AMBA
ports, the bit is set to 1 if RTR.PCTRL.DI = 0.
0
RESERVED