GR740-UM-DS, Nov 2017, Version 1.7
380
www.cobham.com/gaisler
GR740
Table 497.
0x090 - TT3 - Time Stamp Elapsed Time 3 Tx
31
0
TT3
0
r
31: 0
Time Stamp Elapsed Time 3 Tx (TT3) - Time stamped local ET value (96 to 127) when distributed
interrupt transmitted.
Table 498.
0x094 - TT4 - Time Stamp Elapsed Time 4 Tx
31
24 23
0
TT4
RESERVED
0
0
r
r
31: 24
Time Stamp Elapsed Time 4 Tx (TT4) - Time stamped local ET value (128 to 135) when distributed
interrupt transmitted.
23: 0 RESERVED
Table 499.
0x0A0 - LPF- Latency Preamble Field
31
16 15
0
RESERVED
LPF
0
0x2f00
r
r
31: 16
RESERVED
15: 0
Latency Preamble Field (LPF) - The number of coarse and fine time implemented can be obtained
from this Preamble Field.(only for target)
Table 500.
0xA4 - LE0 -Latency Elapsed Time 0
31
0
LE0
0
rw
31: 0
Latency Elapsed Time Value 0 (LE0) - Latency Value (0 to 31) written by initiator.(only for target)
Table 501.
0xA8 - LE1 -Latency Elapsed Time 1
31
0
LE1
0
rw
31: 0
Latency Elapsed Time Value 1 (LE1) - Latency Value (32 to 63) written by initiator.(only for target)
Table 502.
0xAC - LE2 -Latency Elapsed Time 2
31
0
LE2
0
rw
31: 0
Latency Elapsed Time Value 2 (LE2) - Latency Value (64 to 95) written by initiator.(only for target)