GR740-UM-DS, Nov 2017, Version 1.7
203
www.cobham.com/gaisler
GR740
Table 222.
0x00006000 - RTR.PNPPSTRL - SpaceWire Plug-and-Play - Product String Length
31
15 14
0
RESERVED
LEN
0x00000
0x0000
r
r
31: 15
RESERVED
14: 0
Product string length (LEN) - Constant value of 0, indicating that no product string is present.
Table 223.
0x00008000 - RTR.PNPPCNT - SpaceWire Plug-and-Play - Protocol Count
31
5
4
0
RESERVED
PC
0x0000000
0x00
r
r
31: 5
RESERVED
4: 0
Protocol count (PC) - Constant value of 0, indicating that no protocols can be managed by using SpaceWire
Plug-and-Play.
Table 224.
0x0000C000 - RTR.PNPACNT - SpaceWire Plug-and-Play - Application Count
31
8
7
0
RESERVED
AC
0x000000
0x00
r
r
31: 8
RESERVED
7: 0
Application count (AC) - Constant value of 0, indicating that no applications can be managed by using Space-
Wire Plug-and-Play.