![background image](http://html1.mh-extra.com/html/arteche/smart-p500/smart-p500_instruction-manual_2977391352.webp)
IMPLEMENTATION TABLE
0BDNP3 PROTOCOL PROFILE
OBJECT
REQUEST
(Outstation parses)
RESPONSE
(Outstation can
issue)
Obj
Var
Description
Func
Codes
(dec)
Qual
Codes
(hex)
Func
Codes
Qual
Codes
(hex)
22
6
16-Bit Counter Change Event with Time
22
7
32-Bit Delta Counter Change Event with
Time
22
8
16-Bit Delta Counter Change Event with
Time
23
0
Frozen Counter Events - All Variations
23
1
32-Bit Frozen Counter Event without Time
23
2
16-Bit Frozen Counter Event without Time
23
3
32-Bit Frozen Delta Counter Event without
Time
23
4
16-Bit Frozen Delta Counter Event without
Time
23
5
32-Bit Frozen Counter Event with Time
23
6
16-Bit Frozen Counter Event with Time
23
7
32-Bit Frozen Delta Counter Event with
Time
23
8
16-Bit Frozen Delta Counter Event with
Time
30
0
Analog Input - All Variations
1
00,01,06
30
1
32-Bit Analog Input
1
00, 01, 06
129
0, 1
30
2
16-Bit Analog Input
1
00, 01, 06
129
0, 1
30
3
32-Bit Analog Input without flag
30
4
16-Bit Analog Input without flag
31
0
Frozen Analog Input - All Variations
31
1
32-Bit Frozen Analog Input
31
2
16-Bit Frozen Analog Input
31
3
32-Bit Frozen Analog Input with Time of
Freeze
31
4
16-Bit Frozen Analog Input with Time of
Freeze
31
5
32-Bit Frozen Analog Input without Flag
31
6
16-Bit Frozen Analog Input without Flag
32
0
Analog Change Event - All Variations
1
06, 07, 08
32
1
32-Bit Analog Change Event without Time
1
06, 07, 08
129, 130
28
Summary of Contents for smART P500
Page 1: ...Instruction Manual Multifunction Protection Relay smART P500...
Page 23: ...2BTABLES INDEX THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...
Page 39: ...5BHARDWARE FEATURES INTRODUCTION Figure 1 9 Wye Wye Connection measured neutral...
Page 40: ...5BHARDWARE FEATURES INTRODUCTION Figure 1 10 Wye Wye Connection sensitive neutral...
Page 41: ...5BHARDWARE FEATURES INTRODUCTION Figure 1 11 Open Delta Connection measured neutral...
Page 42: ...5BHARDWARE FEATURES INTRODUCTION Figure 1 12 Open Delta Connection sensitive neutral...
Page 511: ...2BANSI CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 6 Moderately ANSI curve...
Page 513: ...2BANSI CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 7 Very inverse ANSI curve...
Page 515: ...2BANSI CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 8 Extremely inverse ANSI curve...
Page 532: ...4BRECLOSER CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 14 Recloser Curves 101 119...
Page 535: ...4BRECLOSER CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 15 Recloser Curves 120 142...
Page 538: ...4BRECLOSER CURVES 0BCURVES FOR TIME CHARACTERISTICS Figure I 16 Recloser Curves 151 202...