background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLUME  

BOOSTER  

 
 
 
  
SITECNA  SRL  
Via G. Di Vittorio 22 
20068 Peschiera Borromeo 
Milan  
Italy 

 

USER’S MANUAL  

MANUALE D’USO 

Part N.   

VB0800000

R

II2GD c IIC T5/T6X

NBR
FKM
EPDM
FVMQ

MAX IN =   10 bar
MAX SIGN = 10 bar
IN/OUT PORT= 1/2"NPT
SIGN PORT= 1/4"NPT

SEALS

Sitecna srl - Milan

     Made in Italy

 www.sitecna.eu

BOOST ER RELAY

FLOW

Part N.   

VB0800088

R

II2GD c IICT6X

NBR
FKM
EPDM
FVMQ

MAX IN =   10 bar
MAX SIGN = 10 bar
IN/OUT PORT= 1/2"NPT
SIGN PORT= 1/4"NPT

SEALS

Sitecna srl - Milan

     Made in Italy

 www.sitecna.eu

BOOST ER RELAY

FLOW

Summary of Contents for VOLUME BOOSTER VB04

Page 1: ...X NBR FKM EPDM FVMQ MAX IN 10 bar MAX SIGN 10 bar IN OUT PORT 1 2 NPT SIGN PORT 1 4 NPT SEALS Sitecna srl Milan Made in Italy www sitecna eu BOOSTER RELAY FLOW Part N VB0800088 R II2GD c IICT6X NBR FKM EPDM FVMQ MAX IN 10 bar MAX SIGN 10 bar IN OUT PORT 1 2 NPT SIGN PORT 1 4 NPT SEALS Sitecna srl Milan Made in Italy www sitecna eu BOOSTER RELAY FLOW ...

Page 2: ...roduct characteristics Caratteristiche Label Targa Specification Specifiche Assembly and items Particolari ed assemblaggio Operation logic Funzionamento Installation caution Norme di Installazione Installation example Esempi di installazione Maintenance Manutenzione Troubleshooting Cosa fare se ...

Page 3: ... 1 Regolazione per mezzo di By pass per aumentare la sicurezza nel controllo della valvola Risposta per piccole variazioni del segnale di ingresso per aumentare la precisione della pressione all attuatore Label Targa Part N Refer to product s model MAX IN Refer to maximum level of supply pressure MAX SIGN Refer to max value of signal IN OUT PORT Refer to port dimension SIGNAL PORT Refer to signal ...

Page 4: ... seguente VB 04 00 00 SS FK 0 Material SS 316 316L Stainless steel AL Epoxy painted aluminum alloy SP Special Option 00 None 88 Threaded exhaust port 0X Special Accessories 0 None 2 SS bracket kit 4 Custom Tag X Special Diaphragm seals material NB NBR WT 20 80 C FK FKM WT 25 90 C LT EPDM WT 40 80 C FL FVQM WT 55 90 C Port 04 NPT 08 NPT ...

Page 5: ... 80 FKM 25 90 EPDM 40 80 FVQM 55 90 MATERIAL ALUMINIUM STAINLESS STEEL AISI316 WEIGHT 0 6 Kg 0 8 Kg 1 5 1 7 Volume Booster Relays VB08 Amplificatore di flusso VB08 TYPE VB08 00 AL VB08 88 AL VB08 00 SS VB08 88 SS MAX SUPPLY PRESSURE 10 bar MAX OUT PUT PRESSURE 10 bar IN OUT PRESSURE RATIO 1 1 FLOW CAPACITY CV IN OUT 2 8 FLOW CAPACITY CV EXH 2 8 IN OUT PORT NPT SIGNAL PORT NPT THREADED EXHAUST NPT ...

Page 6: ...parts and assembly steps for future maintenance POS DESCRIPTION 1 FIXING SCREW THREADED EXHAUST 2 COVER 3 ADJUSTMENT SCREW 4 FIXING SCREW STANDARD MODEL 5 O RING 6 UPPER DIAPHRAGM 7 STANDARD EXHAUSTING RING 8 LOWER DIAPHRAGM ASSEMBLY STD 9 THREADED EXHAUSTING RING 88 OPTION 10 LOWER DIAPHRAGM ASSEMBLY THREADED EXHAUSTING 88 OPTION 11 BODY VB04 VB08 12 VALVE ASSEMBLY 13 SPRING 14 O RING 15 PLUG ...

Page 7: ... by rotating adjust bolt and safety of closed loop system can be enhanced La pressione di alimentazione deve essere fornita all amplificatore ed alla connessione corrispondente al segnale In presenza del segnale il diaframma superiore spinge verso il basso l assieme valvola all interno del tappo guida valvola In queste condizioni l alimentazione viene portata all attuatore attraverso la connession...

Page 8: ...UT IN OUT SIGNAL Dimension Dimensioni Volume Booster Relays VB04 VB08 Volume Booster Relays VB04 88 VB08 88 Amplificatore di flusso VB04 VB08 Amplificatore di flusso VB04 88 VB08 88 MODEL PORT A VB04 NPT VB08 NPT ...

Page 9: ... volume booster in sealed places It is recommended to use appropriate capacity of air filter regulator ATTENZIONE Durante l installazione del prodotto si prega di attenersi alle seguenti procedure Indossare sempre i dispositivi di sicurezza ed attenersi sempre alle procedure di sicurezza Il gas compresso può essere esplosivo e danneggiare il corpo o le parti circostanti la struttura se i valori ma...

Page 10: ...UPPLY OUT IN OUT SIGNAL IN OUT SUPPLY SINGLE ACTING ACTUATOR FR04 VB04 Install Example Esempi di installazione SUPPLY OUT 2 OUT 1 IN OUT SIGNAL IN OUT SIGNAL IN OUT DOUBLE ACTING ACTUATOR FR04 VB04 VB04 ...

Page 11: ...e siano rispettate per evitare incidenti o danni al prodotto Repair kit Kit di riparazione Type VB04 AL SS VB08 AL SS Part number VB 08 K XAL VB 08 K XAL According different type of seals NB NBR FK FKM LT EPDM FL FVQM In funzione dei diversi tipi di guarnizione NB NBR FK FKM LT EPDM FL FVQM When using repair kit all of the parts must be replaced at the same time Partial part replacement may result...

Page 12: ...izionatore Controllare se la pressione di alimentazione dal regolatore al posizionatore e o all amplificatore è costante e corretta controllare se la pressione dell aria viene scaricata dallo scarico del posizionatore verificare se l alimentazione e la sezione di scarico non siano stati ostruiti Funzionamento della valvola instabile quando il segnale è stato inviato dal posizionatore Si prega di r...