Appendix 1 Parameter table
APPENDIX 376
Group
Parameter
Number
Name
Setting Range
Default
Page
06-13
P.281
Input phase loss protection
0: Off
0
1: When input phase loss, inverter stops and
alarms IPF
06-14
P.287
SCP Short circuit protection function
0: Off
1
1: When output side is short, inverter stops
and alarms SCP.
06-15
P.533
PTC alarm action
0: Alarm and continue to run
0
1: Alarm and decelerate to stop
2: Alarm and stop freely
3: No alarm
06-16
P.534
Percentage of PTC level
0~100.0%
0.0%
06-17
P.261
Maintenance alarm function
0: Off
0
1~9998day: Used to set the time for
maintenance alarm output signal
06-18
P.280
Short circuit to ground detection when
starting
0: Off
0
1: When given run command to inverter,
inverter detects short circuit to ground
06-19
P.282
GF detection level when running
280K/315KF and below model:0~100.0%
50.0%
315K/355KF and above model:0~100.0%
70.0%
06-20
P.262
Output phase loss protection
0: Off
0
1: When output phase loss, inverter stops
and alarms LF.
06-21
P.705
Low voltage level
220V inverter : 155~220V
155V
440V inverter : 310~440V
310V
06-22
P.706
Regenerative brake operation level
220V inverter : 205~400V
360V
440V inverter : 410~800V
720V
06-23
P.707
Voltage stall level
220V inverter : 205~400V
380V
440V inverter : 410~800V
760V
06-24
P.708
Capacitor lifetime detection
0: Off
0
Capacitor lifetime detection
1: When the power is OFF, start to detect the
lifetime of capacitor on main circuit.
0
06-25
P.709
Capacitor lifetime detection level
0~100.0%
100.0%
06-26
P.710
Capacitor lifetime detection result
0: Normal.
Read
only
1: Electrolytic capacitor abnormal.
06-27
P.292
Total inverter operation time (minutes) 0~1439 min
0 min
06-28
P.293
Total inverter operation time (days)
0~9999 day
0 day
06-29
P.296
Total inverter power on time (minutes) 0~1439 min
0 min
06-30
P.297
Total inverter power on time (days)
0~9999 day
0 day
06-31
P.298
Output power(lower 16 bit)
Read only
Read
195
06-32
P.299
Output power(higher 16 bit)
Read only
Read
195
06-40
P.288
Alarm record code query
Choose 0~12 recorded alarm
1
06-41
P.289
Alarm record code display
Read only
Read
06-42
P.290
Alarm record message query
Choose 0~10 recorded alarm
0
06-43
P.291
Alarm record message display
Read only
Read