Appendix 1 Parameter table
APPENDIX 375
Group
Parameter
Number
Name
Setting Range
Default Page
05-39
P.395
Second motor load inertia ratio
0~600.0
99999
99999
06-00
P.9
Electronic thermal relay
capacity
0~500.00A: Below frame G
Accordin
g to
frame
0~5000.0A: Frame G and above
06-01
P.22
Stall prevention operation level 0~250.0%
150.0%
06-02
P.23
Stall prevention operation level
correction factor
0~150.0%
99999
99999: Stall prevention operation level is the setting
value of 06-01(P.22).
06-03
P.66
Stall prevention operation
reduction starting frequency
50Hz system: 0~650.00Hz
50.00Hz
60Hz system: 0~650.00Hz
60.00Hz
06-04
P.220
Acceleration and deceleration
time when
current stall
0: According to the
current
Acc/Dec time
3
1: According to the first
Acc/Dec time
2: According to the second Acc/Dec time
3: Automatically calculate proper
Acc/Dec time
06-05
P.30
Regenerative brake selection
0: Brake duty is fixed at 3%, parameter 06-06(P.70)
will be off.
0
1: Brake duty is 06-06(P.70) value.
2:Connect to brake unit(D frame and above)
2
06-06
P.70
Special regenerative brake
duty
0~100.0%
0.0%
06-07
P.263
Decrease carrier protection
setting
0: Fixed carrier frequency, and limit output current
according to carrier value.
0
1: Fixed rated current, and limit carrier according to
output current and temperature.
06-08
P.155
Over torque detection level
0~200.0%
0.0%
06-09
P.156
Over torque detection time
0.1~60.0s
1.0s
06-10
P.260
Action when detect over torque
0: OL2 alarm will not be reported after over torque
detection, and inverter keeps running.
1
1: OL2 alarm will be reported after over torque
detection, and inverter stops.
06-11
P.160
Stall level when restart
0~150.0%
100.0%
06-12
P.245
Cooling fan operation
0X: Inverter shows FAN alarm when fan is damaged.
0
1X: Inverter don’t alarm when fan is damaged, but
the output terminal which is set to function 16
will output a signal.
X0: Fan turn on when inverter starts running. Fan
turn off 30 seconds after inverter stops.
X1: Fan turn on when inverter power on. Fan turn off
when inverter power off.
X2: Fan turn on if heat sink temperature is higher
than 40℃. Fan turn off when inverter power off.
X3: Fan turn on if heat sink temperature is higher
than 60℃. Fan turn off when heat sink
temperature is lower than 40℃.