Motor parameter group 05
PARAMETER DESCRIPTION 174
Measuring
succeed?
If succeed, the operation
panel will display
“TEnd”.
The motor parameter
auto-tuning is finished
Finish
Manually adjust
parameter values
Offset angle of
PM auto-tuning
Y
0
8
N
Y
N
Y
Measuring
sucdeed?
Y
N
If failed, the
operation panel
display“ FAL”.
N
If succeed, the
operation panel will
display “TEnd”.
Confirm the wiring
(Please refer to 3.7
Terminal wire arrangement)
05-00
(
P.301)
Press the forward/reverse rotation key
and start to measure, the operation
panel will display
“TUN”.
3s
Restore display
after
If failed,the
operation panel
display
“FAL”.
PM motor manually input
parameters (05-12
(P.313)
~
05-16
(P.307)
), and then reset
the inverter.
05-00
(P.301)
=9, 00-
21
(P.300)
=5; set the
correct value of 09-
01
(P.350)
and 09-02
(P.351)
.
Press the forward/reverse
rotation key and start to
measure.
3s
Restore display
after
Set motor parameter
(05-01~05-06)
Set motor parameter
(05-01(
P.302)
~
05-06
(
P.307)
)
If need induction motor high accuracy sensorless control, set 05-00(P.301) to 3 for sensorless vector control.
Note: 1. Motor capacity must be the same level or one level lower than inverter capacity.
2. Induction motor automatic measurement: if motor can run freely, set 05-00(P.301) to 1. Load has to be
separated from the motor so the motor can turn freely. If the environment does not permit free run, set
05-00(P.301) to 2 or 5.
3. Induction motor sensorless vector control: automatic measurement function can be used to enhance the
control function. Before setting 05-00(P.301) to 3 or 4, set the motor parameters first and then do automatic
measurement function to improve the control accuracy.
4. When set 05-00(P.301) to 1 (VF + PG), please make sure motor poles 05-02(P.303) is correct.