Appendix 1 Parameter table
APPENDIX 382
Group
Parameter
Number
Name
Setting Range
Default Page
08-35
P.722
PID parameter switch-over deviation
upper limit
0~100.00%
80.00%
08-36
P.723
PID disconnection operation option 1
0: Select no need to run to the upper limit
when PID is disconnected
1
1: Select need to run to the upper limit when
PID is disconnected
08-39
P.726
PID counting when inverter stop action
selection
0: PID stop counting when inverter stop
0
1: PID keep counting when inverter stop
08-40
P.727
PID allowed reverse rotation action
selection
0: PID does not allow reverse rotation
0
1: PID allows reverse rotation
08-41
P.728
PID in reverse direction integral limit
0~100.0%
0.0%
08-42
P.729
PID minimum output frequency
0~10.00Hz
0.00Hz
08-43
P.251
PID pressure range (Bar) setting
1.0~100.0
100.0
08-44
P.252
PID unit selection
0: %
0
1: bar
2: --
3: kgs
4: kg
5: psi
6: Pa
7: kPa
8: MPa
9: C
08-45
P.253
Disconnection detection time feedback
0.0~600.0s
0.0s
08-46
P.254
Disconnection processing method
feedback
0: AEr alarm, inverter free stop
0
1: Slow down and stop, call AEr alarm
2: AEr alerts and continues running
08-50
P.724
PID target linear change time
0~650.00s
0.00s
09-00
P.349
Encoder type
0:ABZ
0
1:ABZ (For synchronous motor)
2:Resolver 1x synchronous motor standard
encoder
3:ABZ/UVW synchronous motor standard
encoder
09-01
P.350
Encoder pulse 1
0~20000
1024
09-02
P.351
Encoder input type 1
0:Off
0
1:A/Phase B pulse wave,forward spin if
Phase A is over Phase B for 90 degrees
2:A/Phase B pulse wave,forward spin if
Phase B is over Phase A for 90 degrees.
3:Phase A :pulse wave,Phase B:directional
sign,L:reverse spin,H:forward spin
4:Phase A :pulse wave,Phase B: directional
sign,L:forward spin,H:reverse spin