Appendix 1 Parameter table
APPENDIX 330
Parameter
Number
Group
Name
Setting Range
Default
Page
P.161
00-07
Multi-function display
14: Reserved.
0
15: Input frequency of terminal HDI. (kHz)
16: Real-time roll diameter. (mm)
17: Real-time line speed. (m/min)
18: Output torque of inverter (%)(Valid only when
00-21 (P. 300) or 00-22 (P. 370) is set to 3 ~ 6 )
19: Digital terminal input state
20: Digital terminal output state
21: Actual working carrier frequency
22: Signal value (mA) of 3-5 input terminals.
(mA/V)
23: Synchronous motor rotor pole position(Show
motor rotor magnetic pole position from encoder
feedback, valid when 00-21 (P. 300) = 5)
24: Current target frequency
25: PTC input percentage
26: Target pressure and feedback pressure from
the constant pressure system
27: Motor rotation speed
28: Power factor
29: Power accumulation rate (kWh)
30: PG feedback rotation speed
31: Motor rotor position (Z pulse as 0)
32: PG card feedback A1 B1 pulse count
33:
PG card feedback A2 B2 pulse count
P.162
01-28
Middle frequency 2
0~650.00Hz
99999
99999: Off
P.163
01-29
Output voltage 2 of
middle frequency
0~100.0%
0.0%
P.164
01-30
Middle frequency 3
0~650.00Hz
99999
99999: Off
P.165
01-31
Output voltage 3 of
middle frequency
0~100.0%
0.0%
P.166
01-32
Middle frequency 4
0~650.00Hz
99999
99999: Off
P.167
01-33
Output voltage 4 of
middle frequency
0~100.0%
0.0%
P.168
01-34
Middle frequency 5
0~650.00Hz
99999
99999: Off
P.169
01-35
Output voltage 5 of
middle frequency
0~100.0%
0.0%
P.170
08-00
PID function selection
0: Off
0
0X: Parameter 08-03(P.225) as target value.
1X: Terminal 2-5 input as target source
2X: Terminal 4-5 input as target source
3X: Terminal 3-5 input as target source