Digital input/ output parameter group 03
PARAMETER DESCRIPTION 142
Group
Parameter
Number
Name
Setting Range
Default Page
03-03
P.80
Terminal M0 input function
Same as 03-00(P.83)
2
03-04
P.81
Terminal M1 input function
Same as 03-00(P.83)
3
03-05
P.82
Terminal M2 input function
Same as 03-00(P.83)
4
03-06
P.126
Terminal M3 input function
Same as 03-00(P.83)
5
03-07
P.127
Terminal M4 input function
Same as 03-00(P.83)
8
03-08
P.128
Terminal M5 input function
Same as 03-00(P.83)
7
03-09
P.550
Terminal HDI input function
Same as 03-00(P.83)
57
03-10
P.40
Terminal SO1-SE output function
0: RUN(Output when inverter running)
1
1: SU(Output when reach target frequency)
2: FU(Output when reach 03-21 03-22 value )
3: OL(Output when overload)
4: OMD(Output when output current is zero)
5: ALARM(Output when alarm)
6: PO1(Output when in program operation step)
7: PO2(Output when in program operation cycle)
8:PO3(Output when in program operation pause)
9: BP(Output when use inverter output in function :
switch between inverter and commercial
power-supply)
10: GP(Output when use commercial
power-supply in function : switch between inverter
and commercial power-supply)
11:OMD1(Output when output current is zero 1)
12~15: Reserved
16: Output when cooling-fan is damaged
17: RY(Output when inverter is powered on and no
alarm)
18: Output when it’s time for maintenance
19: OL2 (Output when overload 2)
20: Output when capacitor abnormal
21:Output when in position control reach position
22:Output when detect curl
in
tension control
23:Output when detect power marker
24~40:
Reserved
41: PID feedback disconnection alarm
03-11
P.85
Terminal A1-B1-C1 output function Same as 03-10(P.40)
5
03-12
P.129
Terminal SO2-SE output function
Same as 03-10(P.40)
2
03-13
P.130
Terminal A2-B2-C2 output function Same as 03-10(P.40)
0
03-14
P.87
Digital input logic
0~1023
0
03-15
P.88
Digital output logic (with expansion
card)
0~4095
0
03-16
P.120
Output signal delay time
0~3600.0s
0.0s
03-17
P.157
Digital input terminal filter time
0~2000ms
4ms
03-18
P.158
Digital input terminal enable when
power on
0: When power on digital terminals work directly
0
1:When power on digital terminals work after
switch off then on