Appendix 1 Parameter table
APPENDIX 349
Parameter
Number
Group
Name
Setting Range
Default Page
P.621
14-23
Material thickness setting source
0:Material thickness is set by parameter 14-24
(P.622)~14-27(P.625)
0
300
1:Material thickness is determined analog value
P.622
14-24
Material thickness 0
0.01~100.00mm
0.01mm
300
P.623
14-25
Material thickness 1
0.01~100.00mm
0.01mm
300
P.624
14-26
Material thickness 2
0.01~100.00mm
0.01mm
300
P.625
14-27
Material thickness 3
0.01~100.00mm
0.01mm
300
P.626
14-28
Maximum thickness
0.01~100.00mm
1.00mm
P.627
14-29
Linear speed input source
0:Off
0
1:Analog value or pulse input
2:Communication setting
P.628
14-30
Maximum linear speed
0.1~6500.0m/min
1000.0m/
min
302
P.629
14-31
Calculate R minimum linear speed 0.1~6500.0m/min
200.0m/
min
302
P.630
14-32
Actual linear speed
0~6500.0m/min
0.0m/min
302
P.633
14-33
Mechanical inertia compensation
coefficiency
0~65535
0
P.634
14-34
Material density
0~60000kg/m3
0kg/ m
3
303
P.635
14-35
Material width
0~60000mm
0mm
303
P.636
14-36
Friction compensation coefficiency 0~50.0%
0.0%
303
P.637
14-37
Material outage detection function
0:Off
0
1:Material outage detection function 1
2:Material outage detection function 2
P.638
14-38
Minimum speed detection
0.1~6500.0m/min
200.0m/
min
304
P.639
14-39
Error range detection
0.1~100.0%
10.0%
304
P.640
14-40
Delay detection
0.1~60.0s
2.0s
304
P.641
08-20
Proportional gain P2
0.1%~1000.0%
20.0%
P.642
08-21
Integral time I2
0~60.00s
1.00s
P.643
08-22
Differential time D2
0~10000ms
0ms
P.644
08-23
Auto adjustment for PID
parameters
0:Adjust according to the feedback deviation value
0
1: Adjust according to the curling radius.
2: Adjust according to the operation frequency
3: Adjust according to the line speed
P.645
14-41
Pre-drive speed gain
-50.0%~50.0%
0.0%
P.646
14-42
Pre-drive torque increase
-50.0%~50.0%
0.0%
305
P.647
14-43
Pre-drive delay
0~65535ms
0ms
305
P.650
14-12
Calculate winding memory control
by thickness calculation
0:Do not save winding radius when power outage
or calculation stops
0
1:Save winding radius when there’s a power
outage or calculation stops,and use saved winding
radius as initial winding radius when power
recovers or calculation restarts