Speed and torque control parameter group 11
PARAMETER DESCRIPTION 272
5.12.1 Control parameter
When inverter runs in different frequencies, select and set different speed Loop PI parameters.
Parameter
Name
Default
Setting Range
Content
11-00
P.320
Speed control proportional
coefficient 1
100.0
0~2000.0
---
11-01
P.321
Speed control integral time 1
0.30s
0~20.00s
---
11-02
P.322
PI coefficient switch-over
frequency 1
5.00Hz
0~
11-05(P.325)Hz
---
11-03
P.323
Speed control proportional
coefficient 2
100.0
0~2000.0
---
11-04
P.324
Speed control integral time 2
0.30s
0~20.00s
---
11-05
P.325
PI coefficient switch-over
frequency 2
5.00Hz
11-02(P.322)~
650.00Hz
---
11-06
P.326
Current control proportional
coefficient
0
0~20
This parameter decides the response
characteristics in IM motor torque control.
11-23
P.412
Zero-speed proportional
coefficient
100.0
0~2000.0
---
11-24
P.413
Zero-speed integral time
0.30s
0~20.00s
---
11-25
P.414
Zero-speed switching
frequency
5.00Hz
0~650.00Hz
---
Control parameter
11-00(P.320) and 11-01(P.321) are PI adjustment parameters when operating frequency is less than switching
frequency 1 (11-02(P.322)), while 11-03(P.323) and 11-04(P.324) are PI adjustment parameters when the
operating frequency is greater than switching frequency 2 (11-05(P.325)). The PI parameters of the frequency
band between switching frequency 1 and switching frequency 2 are linear switching of two groups of PI
parameters. As shown in the following diagram:
0
Th
e c
oe
fic
ie
nt
P s
w
itc
he
s
fro
m
1
1-2
3 (
P.4
12
) to
11
-0
0 (
P.3
20
) l
ine
arl
y
Th
e c
oe
fic
ie
nt
I s
w
itc
he
s
fro
m
1
1-2
4 (
P.4
13
) to
11
-0
1 (
P.3
21
) l
ine
arl
y
Th
e c
oe
fic
ie
nt
P s
w
itc
he
s
fro
m
1
1-0
0 (
P.3
20
) to
11
-0
3 (
P.3
23
) l
ine
arl
y
Th
e c
oe
fic
ie
nt
I s
w
itc
he
s
fro
m
1
1-0
1 (
P.3
21
) to
11
-0
4 (
P.3
24
) l
ine
arl
y
11-00(P.320) / 11-03(P.323) is used to set the proportion gain of speed control.(Set the value slightly larger to
better follow changes on the speed reference and to reduce speed change due to external interference.)
11-01(P.321) / 11-04(P.324) is used to set the integral time of speed control.(Due to external
interference-generated speed change, set the value smaller to shorten the time spent on returning to the original
speed.)
When 11-06(P.326) is set to 100%, the max output torque in vector control is the motor rated torque.
Setting
Содержание SA3 Series
Страница 2: ......
Страница 420: ...Appendix 6 European Specification Compatibility Description APPENDIX 418 ...
Страница 421: ...Appendix 6 European Specification Compatibility Description Appendix 419 ...