Multi-speed parameter group 04
PARAMETER DESCRIPTION 163
5.5.1 16 steps speed
With the combination of digital input terminal RL, RM, RH and REX, 16 steps speed can be selected (up to 16
speeds)
Parameter
Name
Default Setting Range
Content
04-00
P.4
Speed1(high speed)
60.00Hz
0~650.00Hz
---
04-01
P.5
Speed2(medium
speed)
30.00Hz
0~650.00Hz
---
04-02
P.6
Speed3(low speed)
10.00Hz
0~650.00Hz
---
04-03
P.24
Speed4
99999
0~650.00Hz
---
99999
99999: Off
04-04
P.25
Speed5
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-05
P.26
Speed6
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-06
P.27
Speed7
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-07
P.142
Speed8
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-08
P.143
Speed9
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-09
P.144
Speed10
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-10
P.145
Speed11
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-11
P.146
Speed12
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-12
P.147
Speed13
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-13
P.148
Speed14
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
04-14
P.149
Speed15
99999
Same as
04-03(P.24)
Same as 04-03(P.24)
16 steps speed
If all the values of 04-03
(P.24)
~04-06(P.27) and 04-07(P.142)~04-14(P.149) are not 99999, “16 steps speed” is
active. It means with the combination of RL, RM, RH and REX, there are 16 speeds in total. To set target
frequency for inverter, please refer to the figure below:
Setting
Содержание SA3 Series
Страница 2: ......
Страница 420: ...Appendix 6 European Specification Compatibility Description APPENDIX 418 ...