Digital input/ output parameter group 03
PARAMETER DESCRIPTION 152
5.4.3 Terminal logic selection
This function is set in bits, if bit shows 1, it means the correspond terminal is negative logic; if bit shows 0, it means
the correspond terminal is positive logic.
Parameter
Name
Default Setting Range
Content
03-14
P.87
Digital input logic
0
0~1023
---
03-15
P.88
Digital output logic
(with expansion card)
0
0~4095
---
Digital input/output logic
The definition of each bit in 03-14(P.87) is as follows:
2
0
2
5
2
4
2
3
2
2
2
1
STF
STR
M0
M1
M2
RES
bit
2
6
2
7
2
8
M3
M4
M5
HDI
2
9
For example, customer require M0(RL) button needs to be normal close (negative logic). Therefore, the setting of
parameter 03-14(P.87) should be as follows:
2
0
2
5
2
4
2
3
2
2
2
1
0
0
1
0
0
0
bit
2
6
2
7
2
8
0
0
0
0
2
9
So (03-14)P.87= 0×2
5
+ 0×2
4
+ 0×2
3
+ 1×2
2
+ 0×2
1
+ 0×2
0
= 4
The definition of each bit in 03-15(P.88) is as follows :
bit
SO1
SO2 ABC1
ABC2
ABC10
ABC11
ABC12
ABC13
ABC14
ABC15
ABC16
ABC17
2
0
2
8
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
9
2
10
2
11
SLOT3 expanded
digital output
For example: 03-11(P.85)=0 RUN(Output when inverter running), if A1-B1-C1 bit is set to 0(positive logic), when
inverter runs, A1-B1-C1 ON, when inverter stops, A1-B1-C1 OFF. If A1-B1-C1 bit is set to 1(negative logic), when
inverter runs, A1-B1-C1 OFF, when inverter stops, A1-B1-C1 ON.
Note: If “STF” and “STR” terminals are set to negative logic, but signal is not connected to SD, when power on,
inverter will output directly. This is a potential danger,
please check 03-18(P.158) to overcome this problem.
Setting