Appendix 1 Parameter table
APPENDIX 323
Parameter
Number
Group
Name
Setting Range
Default
Page
P.79
00-16
Operation mode selection
0: “PU mode”, “external mode” and “Jog mode”
are interchangeable.
0
1: “PU mode” and “JOG mode” are
interchangeable.
2: “External mode” only
3: “Communication mode” only
4: “Combined mode 1”
5: “Combined mode 2”
6: “Combined mode 3”
7: “Combined mode 4
8: “Combined mode 5”
99999: Second operation mode, run command is
set by 00-18(P.109), target frequency is set by
00-17(P.97)
P.80
03-03
Terminal M0 input
function
Same as 03-00(P.83)
2
P.81
03-04
Terminal M1 input
function
Same as 03-00(P.83)
3
P.82
03-05
Terminal M2 input
function
Same as 03-00(P.83)
4
P.83
03-00
Terminal
STF
input
function
0: STF(Inverter runs forward)
0
1: STR(Inverter runs reverse)
2: RL(Multi-speed low speed)
3: RM(Multi-speed medium speed)
4: RH(Multi-speed high speed)
5:AU( Analog terminal 4-5 high priority)
6: External thermal relay actuate
7: MRS(Stops inverter output immediately)
8: RT(Inverter second function)
9: EXT(External JOG)
10: STF+EXJ
11: STR+EXJ
12: STF+RT
13: STR+RT
14: STF+RL
15: STR+RL
16: STF+RM
17: STR+RM
18: STF+RH
19: STR+RH
20: STF+RL+RM
21: STR+RL+RM
22: STF+RT+RL
23: STR+RT+RL