Unicont SPb Ltd 

 

 

 

 

 

 

 

 

Analog digital programmable converter 

ADPC-101 

 

Technical Documentation

 

(101-4-30102013) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

St. Petersburg

 

2013

 

v.4.1 

Содержание ADPC-101

Страница 1: ...Unicont SPb Ltd Analog digital programmable converter ADPC 101 Technical Documentation 101 4 30102013 St Petersburg 2013 v 4 1...

Страница 2: ...LATION 5 5 UNIT OPERATION 11 6 AUXILIARY MODE FOR DISPLAY OF SIGNAL STATUS AT INPUT TERMINALS 12 7 ADDITIONAL DISPLAYING MODES 13 8 MENU FUNCTIONS AND CHANGING OF SETTINGS 13 9 EXAMPLE OF CONNECTING A...

Страница 3: ...g contact Indication of current speed and course values in built in display Conversion of received data into NMEA 0183 format Transmission of converted course and speed data via standard interface RS...

Страница 4: ...s 1 or 2 NMEA refresh 1 2 5 10Hz 2 Output signal format standard line NMEA 0183 with line checksum number of options for line output 63 sets by 3 separate options 3 Format parameters Data bit 8 bit Ra...

Страница 5: ...cleaning of device surface to avoid damages of applied decals Prohibited to use device in floor mounted position to expose device for mechanical shocks and tensioning of power supply cable to use faul...

Страница 6: ...panel on mounted casing tighten gland seals of cable entries Arrangement of terminal strips on the board and purpose of contacts are stated in Figure 2 Wiring diagram for power supply source output c...

Страница 7: ...cted jointly and further are connected to a common gyrocompass wire GND and compass outputs are connected to relevant inputs as designated 2 Inputs for log 2 1 Inputs for log with interface on closing...

Страница 8: ...itches J4 J5 J6 J7 J8 or jumpers With closed contacts threshold input voltage is approximately 6 V and about 3V with open contacts J4 J5 J6 J7 J8 or input voltage is approximately 3V input voltage is...

Страница 9: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 9 Figure 3 Wiring diagram for synchro type gyrocompass...

Страница 10: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 10 Figure 4 Wiring diagram for stepper type gyrocompass...

Страница 11: ...gyrocompass in use Should received values of compass and log are not trustworthy display with show the sign question at the beginning of relevant line indicator readings during device power ON mode o...

Страница 12: ...or OFF there will be an automatic exit from input mode to review mode of course and speed values without changing of any option Selected options are preserved only after depression on ENTER After sele...

Страница 13: ...in NMEA data output in this mode does not stop or change 7 2 Displaying of ROT rate of turn In this mode display shows current rate of turn of a ship After activating this mode lower string of display...

Страница 14: ...negative as far as synchro type compass is concerned selection of negative polarity causes signal inversion and operation for signal edge shift by 180 degrees as far as stepper type gyrocompass is co...

Страница 15: ...backlighting and exit from menu of options or input mode in case of operator idling 5 second 10 second 15 second 20 second 25 second OFF 8 7 Alarm tuning Alarm ON OFF If option is setted device is emi...

Страница 16: ...absence of reference signal As far as stepper type gyrocompass is concerned lack of required level As far as synchro type gyrocompass is concerned lack of sine signal differentials emergence of timin...

Страница 17: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 17 9 Example of connecting ADPC 101...

Страница 18: ...sport automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in acco...

Страница 19: ...es You can also send the overage equipment to the manufacturer for its further recycling Proper recycling of the product components will prevent potential negative consequences for human health and th...

Страница 20: ...nmarketable condition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who...

Страница 21: ...serial number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control...