UM10503
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
User manual
Rev. 1.3 — 6 July 2012
67 of 1269
NXP Semiconductors
UM10503
Chapter 8: LPC43xx Event router
7
WWDT_E
Edge/level detect mode for WWDTD event. The
corresponding bit in the EDGE register must be 0.
0
0
Level detect.
1
Edge detect of the WWDT interrupt. Detect falling edge if
bit 7 in the HILO register is 0. Detect rising edge if bit 7 in
the HILO register is 1.
8
ETH_E
Edge/level detect mode for ethernet event. The
corresponding bit in the EDGE register must be 0.
0
0
Level detect.
1
Edge detect of the Ethernet interrupt. Detect falling edge
if bit 8 in the HILO register is 0. Detect rising edge if bit 8
in the HILO register is 1.
9
USB0_E
Edge/level detect mode for USB0 event. The
corresponding bit in the EDGE register must be 0.
0
0
Level detect.
1
Edge detect of the USB0 event. Detect falling edge if bit
9 in the HILO register is 0. Detect rising edge if bit 9 in
the HILO register is 1.
10
USB1_E
Edge/level detect mode for USB1 event. The
corresponding bit in the EDGE register must be 0.
0
0
Level detect.
1
Edge detect of the USB1 interrupt. Detect falling edge if
bit 10 in the HILO register is 0. Detect rising edge if bit 10
in the HILO register is 1.
11
SDMMC_E
Edge/level detect mode for SD/MMC event.The
corresponding bit in the EDGE register must be 0.
0
Level detect.
1
Edge detect of the SD/MMC interrupt. Detect falling edge
if bit 10 in the HILO register is 0. Detect rising edge if bit
10 in the HILO register is 1.
12
CAN_E
Edge/level detect mode for C_CAN event. The
corresponding bit in the EDGE register must be 0.
0
0
Level detect.
1
Edge detect of the combined C_CAN interrupt. Detect
falling edge if bit 12 in the HILO register is 0. Detect
rising edge if bit 12 in the HILO register is 1.
13
TIM2_E
Edge/level detect mode for combined timer output 2
event. The corresponding bit in the EDGE register must
be 0.
0
0
Level detect.
1
Edge detect of GIMA output 25. Detect falling edge if bit
13 in the HILO register is 0. Detect rising edge if bit 13 in
the HILO register is 1.
Table 34.
Edge configuration register (EDGE - address 0x4004 4004) bit description
Bit
Symbol
Value Description
Reset
value