1 RUNNING A PROGRAM
1.2 Scan Time
Setting method
The device/label access service processing can be configured as follows.
[CPU Parameter]
[Service Processing Setting]
[Device/Label Access Service Processing Setting]
Window
Displayed items
Item
Description
Setting range
Default
Specifying
Method
Select a method for specifying the service processing for access to
devices/labels.
• Execute the Process as Scan Time
Proceeds
• Set Processing Time
• Set Processing Counts
• Execute END Processing between
Programs
Execute the
Process as Scan
Time Proceeds
Rate
Set the ratio of the device/label access service processing to execute
during a single scan when "Execute the Process as Scan Time
Proceeds" is enabled. The device/label access service processing time
is determined based on the scan time.
1 to 99% (unit: 1%)
10%
Time
Set the device/label access service processing time per scan when
"Set Processing Time" is enabled
0.1 to 1000ms (unit: 0.1ms)
0.1ms
Counts
Set the number of executions of the device/label access service
processing per scan when "Set Processing Counts" is enabled.
1 to 10 times (unit: 1 time)
1 time
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......