![Mitsubishi Electric MELSEC iQ-R-R00CPU Скачать руководство пользователя страница 291](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r-r00cpu/melsec-iq-r-r00cpu_user-manual_239139291.webp)
16 MULTIPLE CPU SYSTEM FUNCTION
16.1 Out-of-group I/O Fetch
289
16
16.1
Out-of-group I/O Fetch
The access range to the controlled module is different from that to the non-controlled module. To fetch the data which cannot
be accessed, use the out-of-group I/O fetch function.
Accessing controlled module
The access range to the controlled module of the CPU module is the same as that to the single CPU system, and I/O refresh
for the controlled module and/or reading/writing to buffer memory of the intelligent function module are enabled.
Accessing non-controlled module
Access to the non-controlled module of the CPU module is limited to reading input (DX) and buffer memory of the intelligent
function module. Note that On/Off data of input (X)/output (Y) of the non-controlled module can be fetched using the out-of-
group I/O Fetch function. (
Page 290 Out-of-group I/O fetch setting)
: Accessible,
: Not accessible
*1 Cannot read from CPU modules which are synchronized through the inter-module synchronization function.
Precautions
An error is not detected in reading input (DX) for the non-controlled module and buffer memory of the intelligent function
module.
Communication
method
Access target
Access range
When "Import" is selected in
the settings for out-of-group I/O
fetch
When "Not Imported" is
selected in the settings for out-
of-group I/O fetch
Communication
through refresh
Input (X)
Read to another
CPU module
(Non-processing)
Output (Y)
Write to another
CPU module
(Non-processing)
Read to another
CPU module
The buffer memory of the
intelligent function module
Read
(Cannot be specified from
engineering tools)
(Cannot be specified from
engineering tools)
Write
Link direct device
Read
(Cannot be specified from
engineering tools)
(Cannot be specified from
engineering tools)
Write
Communication
through direct
access
Input (DX)
Read to another
CPU module
Output (DY)
Write to another
CPU module
(Non-processing)
(Non-processing)
Read to another
CPU module
(Cannot be specified)
(Cannot be specified)
The buffer memory of the
intelligent function module
Read
Write
(An error occurs in the CPU
module.)
(An error occurs in the CPU
module.)
Link direct device
Read
(An error occurs.)
(An error occurs.)
Write
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......