Appendix 4 List of Special Relay Areas
*1 The programmable controller CPU with firmware version "28" or later supports these special relay areas. However, there are no
restrictions on the version of the R00CPU, R01CPU, and R02CPU.
*2 There are restrictions on the firmware version of the supported CPU module and software version of the engineering tool. (
1008 Added and Enhanced Functions)
SM796
Number of used blocks
information for the multiple
CPU dedicated instruction
(for CPU No.1)
Off: The specified number
of blocks is reserved
On: The number of blocks
specified in SD796 is
not reserved
• This relay switches to on when the
number of remaining blocks in the
dedicated instruction transfer area to be
used in the multiple CPU dedicated
instruction (target machine: CPU No.1)
drops below the number of blocks
specified in SD796. This relay is also on
when the instruction is being executed.
• This relay switches to off when there exist
free blocks during the END processing.
S (Instruction execution/
During END)
Rn
RnP
RnSF
SM797
Number of used blocks
information for the multiple
CPU dedicated instruction
(for CPU No.2)
Off: The specified number
of blocks is reserved
On: The number of blocks
specified in SD797 is
not reserved
• This relay switches to on when the
number of remaining blocks in the
dedicated instruction transfer area to be
used in the multiple CPU dedicated
instruction (target machine: CPU No.2)
drops below the number of blocks
specified in SD797. This relay is also on
when the instruction is being executed.
• This relay switches to off when there exist
free blocks during the END processing.
S (Instruction execution/
During END)
Rn
RnP
RnSF
SM798
Number of used blocks
information for the multiple
CPU dedicated instruction
(for CPU No.3)
Off: The specified number
of blocks is reserved
On: The number of blocks
specified in SD798 is
not reserved
• This relay switches to on when the
number of remaining blocks in the
dedicated instruction transfer area to be
used in the multiple CPU dedicated
instruction (target machine: CPU No.3)
drops below the number of blocks
specified in SD798. This relay is also on
when the instruction is being executed.
• This relay switches to off when there exist
free blocks during the END processing.
S (Instruction execution/
During END)
Rn
RnP
RnSF
SM799
Number of used blocks
information for the multiple
CPU dedicated instruction
(for CPU No.4)
Off: The specified number
of blocks is reserved
On: The number of blocks
specified in SD799 is
not reserved
• This relay switches to on when the
number of remaining blocks in the
dedicated instruction transfer area to be
used in the multiple CPU dedicated
instruction (target machine: CPU No.4)
drops below the number of blocks
specified in SD799. This relay is also on
when the instruction is being executed.
• This relay switches to off when there exist
free blocks during the END processing.
S (Instruction execution/
During END)
Rn
RnP
RnSF
SM816
Hold mode (S.IN
instruction)
Off: Value not held
On: Value held
Whether to hold the output value or not is
specified when the input value is found to be
exceeding the valid range during the range
check processing of the S.IN instruction.
U
RnP
RnPSF
SM817
Hold mode (S.OUT
instruction)
Off: Value not held
On: Value held
This relay is used to specify whether or not
to hold the output values of the S.OUT1,
S.OUT2, and S.DUTY instructions if a
sensor error occurs.
U
RnP
RnPSF
No.
Name
Data stored
Details
Set by (setting timing) CPU
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......