37 FUNCTIONS
Functions
different
(modified or
restricted) from
Part 2
Process control function
Process control function blocks and process control instructions can be used
only in standard programs.
MELSEC iQ-R
Programming Manual
(Process Control
Function Blocks/
Instructions)
Label
initialization
function
Label
initialization
after converting
all programs
Safety labels and standard/safety shared labels are not applicable as only
standard labels are supported.
Label
initialization
with label initial
values
Label access setting from
external device
• In the transfer setup of external devices that communicate with the CPU
module through GOT, SLMP, or other methods, select "Control System/
Standby System", "System A/System B", or "Not Specified" to start a
communication with a global label name specified.
• Safety global labels or standard/safety shared labels cannot be specified in
the global label settings.
Latch function
• When the systems are switched, the new control system and the new
standby system start the value in "Interval Setting at Time Setting" in
"Device Latch Interval Setting" from 0.
• Safety devices, safety labels, and standard/safety shared labels cannot be
latched.
Device/label initial value setting
An initial value cannot be set for safety global devices, safety local devices,
safety global labels, safety local labels, and standard/safety shared labels. To
set an initial value for those devices or labels, create a program so that the
safety state can be secured and the value is set only at start-up.
Device/label access service
processing setting
Even though this function is set, the scan time of some functions (operations)
becomes longer than the specified time. The following are added to those
functions.
• Safety local devices (label) batch/registration monitor
• Current value change of the safety labels/safety devices
• Switching safety operation mode
• Safety data identify check
SLMP communications
• There are notes for system switching when the system IP address
matching function is not used.
• If a remote operation command is executed, the CPU modules enter
different operating statuses and thus systems cannot be switched.
• For SLMP communications via the built-in Ethernet port of the CPU
module, when communications are performed to the other system that
cannot respond (power-off, reset, or tracking cable disconnection), a
timeout error may occur.
• Safety devices cannot be accessed. Also, the command execution status
differs.
Ethernet
function
File transfer
function (FTP
server)
Safety devices cannot be accessed. Also, the command execution status
differs.
Page 587 File operation
available
Function
Description
Reference
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......