958
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
*1 The following capacity values are output to
based on the model.
Example: R08CPU, R08ENCPU, R08PCPU, R08SFCPU:
= 08
(16)
Device comment
name length
The length of the device comment name specified in the setting is output.
2
(17)
Device comment
name
The device comment name specified in the setting is output in Unicode.
When "Output each program device comment" is selected, the comment with the specified comment
number in the device comment file for each program is output only for the local device.
When the device comment file for each program or the comment of the corresponding program does
not exist, the comment of the device comment file is output.
0 to 2048
(18)
Record start flag,
record end flag
The flags for identifying the start and end of the record are output. The FFFFH is output for record start
while the FFFEH is output for record end as the fixed flag.
2
(19)
Record data length
The total size of (20) Day and time data to (28) Last data is output.
2
(20)
Date data
The Day and time data is output.
8
(21)
Data collection
interval
The time interval from the previous collection time to the current collection time is output. (Unit:
s,
Display range: 1 to 100000000000 (When it exceeds the max value, it returns to "1" and incrementing
runs again.)) After logging collection is started, 0 is stored at the first collection.
8
(22)
Step No.
The step No. executed with the engineering tool at the timing in which data was collected is output. With
the collection condition "Each scanning cycle" specified, the resulting output is the step No. at the time
of execution of END instruction in the last executed program on the scan. With the collection condition
"Interrupt occurrence" specified, the resulting output is the step No. at the time of execution of IRET
instruction in the interrupt program. If the system operation (such as system interrupt) is running during
collection interval and collection timing or the FB program is in running, "0" is output.
4
(23)
Program No.
The program No. (FB File No) executed on the engineering tool at the timing in which data was
collected is output. With the collection condition "Each scanning cycle" specified, the resulting output is
the program number of the last executed program in the scan. If system operation (such as system
interrupt) is running at collection interval and collection timing, "0" is output.
2
(24)
Program name
length
The name length of a program that is executed at the time interval and timing in which data was
collected is output. If the same program number or program name has already been in the file, "0" is
output.
2
(25)
Program name
The program name (no extension) that is executed at the time interval and timing in which data was
collected is output in Unicode. With the collection condition "Each scanning cycle" specified, the
resulting output is the program name of the last executed program in the scan. If system operation
(such as system interrupt) is running at collection interval and collection timing, "* SYSTEM" is output.
0 to 200
(26)
Index
The index number ranging from 1 to 4294967295 of data, which was collected by the data logging
function, is output. When it exceeds the max value, it returns to "1" and incrementing runs again. If
missing occurs in processing data, index will be reassigned from 1 again.
4
(27)
Trigger occurrence
flag
The trigger occurrence information is output.
b0 1: A trigger has occurred.
0: No trigger has occurred.
2
(28)
Data
Data collected by the data logging function is output corresponding to (13) Data length and (10) Data
type.
• When bits are specified: bit On = 1 and bit Off = 0 are output.
• When word type (signed/unsigned) or double-word type (signed/unsigned) is specified: the data
values are output in the specified unit.
• When single-precision real number or double-precision real number is specified: data value is output
in the specified unit. (
Page 959 Numerical value range for each output type)
• When character string type is specified: the character string with the specified size is output. If the
character string terminator "0" exists in the middle of data, NULL is generated on from said point
onward until the terminator of the specified size.
• When numeric string type is specified: the data value with the specified size is output.
• When time is specified: T#-24d20h31m23s648ms to T#24d20h31m23s647ms is output.
• Bit: 2
• Word (signed/
unsigned): 2
• Double word
(signed/
unsigned): 4
• Single-precision
real number: 4
• Double-precision
real number: 8
• String/numeric
string: 1 to 256
• Time: 4
(29)
Device code
The device code of the device/label specified in the setting is output.
16
(30)
Program name
length
The length of the program name specified in the setting is output. (When a global device or global label
is specified, "0" is output.)
2
(31)
Program name
The specified program name (no extension) is output in Unicode. (When a global device or global label
is specified, the program name is not output.)
0 to 120
No.
Item
Description
Size (byte)
b15
b0
to
Year: Last 2 digits of the year,
Month: 1 to 12
Day: 1 to 31, Time: 0 to 23
Minute: 0 to 59, Second: 0 to 59
Millisecond: 0 to 999
Year
Day
Minute
Month
Time
Second
Millisecond
b0
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......