APPX
Appendix 7 List of Safety Special Register Areas
887
A
SA\SD1040
to
SA\SD1047
Safety refresh
status of each
safety connection
(5th module)
0: Safety
communications
normal, safety
connection not
used, own
station
1: Communication
error
• The communication status of safety stations connected to the 5th
CC-Link IE Field Network module (the one whose start I/O number is
stored in SD1908) is stored.
• A communication error means that the safety station is not in any of
the communication states stored in SA\SD1104 to SA\SD1223.
The bit arrangement of the safety connection number is the same as
that of the 1st module. (Note that the SA\SD numbers differ.)
S (Status
change)
RnPSF
RnSF
SA\SD1048
to
SA\SD1055
Safety refresh
status of each
safety connection
(6th module)
0: Safety
communications
normal, safety
connection not
used, own
station
1: Communication
error
• The communication status of safety stations connected to the 6th
CC-Link IE Field Network module (the one whose start I/O number is
stored in SD1909) is stored.
• A communication error means that the safety station is not in any of
the communication states stored in SA\SD1104 to SA\SD1223.
The bit arrangement of the safety connection number is the same as
that of the 1st module. (Note that the SA\SD numbers differ.)
S (Status
change)
RnPSF
RnSF
SA\SD1056
to
SA\SD1063
Safety refresh
status of each
safety connection
(7th module)
0: Safety
communications
normal, safety
connection not
used, own
station
1: Communication
error
• The communication status of safety stations connected to the 7th
CC-Link IE Field Network module (the one whose start I/O number is
stored in SD1910) is stored.
• A communication error means that the safety station is not in any of
the communication states stored in SA\SD1104 to SA\SD1223.
The bit arrangement of the safety connection number is the same as
that of the 1st module. (Note that the SA\SD numbers differ.)
S (Status
change)
RnPSF
RnSF
SA\SD1064
to
SA\SD1071
Safety refresh
communication
status of each
safety connection
(8th module)
0: Safety
communications
normal, safety
connection not
used, own
station
1: Communication
error
• The communication status of safety stations connected to the 8th
CC-Link IE Field Network module (the one whose start I/O number is
stored in SD1911) is stored.
• A communication error means that the safety station is not in any of
the communication states stored in SA\SD1104 to SA\SD1223.
The bit arrangement of the safety connection number is the same as
that of the 1st module. (Note that the SA\SD numbers differ.)
S (Status
change)
RnPSF
RnSF
SA\SD1088
CC-Link IE Field
safety
communications
information storage
area module
specification
1 to 8:Target
module
• The CC-Link IE Field Network master/local module targeted for
safety communication status check is specified.
• To reflect the value set in this register, turn on SA\SM1088.
• If an unmounted module is specified, 0 is stored in SA\SD1090 to
SA\SD1097 and SA\SD1104 to SA\SD1223.
U
(Request)
RnPSF
RnSF
SA\SD1089
CC-Link IE Field
safety
communications
information storage
area module
1 to 8:Target
module
• The module number specified in SA\SD1088 is stored.
• Data for the module displayed in this register is stored in SA\SD1090
to SA\SD1097 and SA\SD1104 to SA\SD1223.
S (Status
change)
RnPSF
RnSF
SA\SD1090
to
SA\SD1097
Safety
communication
setting of each
safety connection
(1st to 8th module)
0: Not set
1: Set
The safety communication setting status of safety connections of the
module stored in SA\SD1089 is stored.
1 to 120: Safety connection number
: Fixed to 0
S (Initial)
RnPSF
RnSF
No.
Name
Data stored
Details
Set by
(setting
timing)
CPU
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
112 111 110 109 108 107 106 105 104 103 102 101 100 99
98
97
120 119 118 117 116 115 114 113
SA\SD1090
SA\SD1091
SA\SD1092
SA\SD1093
SA\SD1094
SA\SD1095
SA\SD1096
SA\SD1097
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......