3 MEMORY CONFIGURATION OF THE CPU MODULE
3.4 Files
105
3
File size
The following table lists the size of files that can be stored in the CPU module.
*1 Up to 3 bytes are added to the total file size so that the size will be a multiple of 4 bytes.
File type
File size
Program
Approx. 4050 bytes minimum (only the END instr 500 steps reserved for online program
change)
FB file
Approx. 4900 bytes minimum (non-processing FB + 500 steps reserved for online program change)
CPU parameter
744 bytes minimum
System parameter
112 bytes minimum
Module parameter
The size differs depending on the module used. For example, the size is 1036 bytes at minimum
when the Ethernet function is used.
Module extension parameter
The size differs depending on the module used. For example, the size is 65572 bytes when the
predefined protocol support function is used with the Ethernet function.
Module-specific backup parameter
The size differs depending on the module used.
Memory card parameter
124 bytes minimum
Device comment
220 bytes minimum (when a device comment with 20 characters is set in a device)
Initial device value
Approx. 140 bytes minimum (when the initial value of a word device is set)
Global label setting file
Approx. 660 bytes minimum (when a word-type global label is set)
Initial label value file
Initial global label value file
Approx. 140 bytes minimum (when the initial value of a word-type global label is set)
Initial local label value file
File register
2048 bytes minimum (when the setting capacity is 1K words)
Event history
1024 bytes minimum (when the setting capacity is 1K bytes (default setting is 131072 bytes))
Device data storage file
2048 bytes minimum (when the setting capacity is 1K words)
General-purpose data
The size differs depending on the size of the file to be written.
Data logging setting file
Common setting file
142 bytes (When the setting is configured so that one-word data is collected in a binary file at each
scan in continuous logging)
Individual setting file
1192 bytes (When the setting is configured so that one-word data is collected in a binary file at each
scan in continuous logging only for setting No.1)
Memory dump setting file
1224 bytes (when the save file name is "MEMDUMP_00")
Remote password
224 bytes minimum
Faulty database check file
Total number of characters in the file path
2 bytes + number of databases
4 bytes
System file for backing up CPU module data
20 + 12 + ((N1
34) + (N2
34) + (N3
34)) + M + 8 bytes
N1: Number of target drives
N2: Number of target files
N3: Number of target folders
M: Total name size of target files/folders (bytes) (including ".", extensions, but no drive symbols)
Backup data file for backing up CPU module data
When the data logging setting has been registered: 30608 bytes
When the data logging setting has not been registered: 30200 bytes
Device/label data file for backing up CPU module data
■
When local devices are not set
• 20 + 20 + (N1
142) + 16 + (N2
134) + (16 + (162 + (N3
18) + 1 M1)) + 28 + M3 +
M4 + M5 + 8 bytes
■
When local devices are set
• 20 + 20 + (N1
142) + 16 + (N2
134) + (16 + (162 + (N3
18) + 1 M1)) + (16 + N1
(8 + ((N4
18) + M2))) + 28 + M3 + M4 + M5 + 8 bytes
N1: Number of programs
N2: Number of file registers
N3: Number of set device types (excluding SM, SD, FX, FY, FD, X, Y, and G/HG)
N4: Number of local device settings (Number of device types)
M1: Total size of set devices (bytes) (excluding SM, SD, FX, FY, FD, X, Y, and G/HG)
M2: Total size of local devices (bytes)
M3: Module label size (bytes)
M4: Label area size (bytes)
M5: Latch label area size (bytes)
System file for the iQ Sensor Solution data backup/
restoration function
36 + 20
N bytes (N: No. of devices supporting iQSS whose data has successfully been backed up)
Backup data file for the iQ Sensor Solution data backup/
restoration function
Depends on the devices supporting iQSS.
ODBC server setting file
236 bytes (when the IP address of the CPU module is 192.168.3.39)
Database path file
Total number of characters in the file path
2 bytes + number of databases
4 bytes
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......