APPX
Appendix 1 Error Codes
787
A
Codes of errors detected by other than the self-diagnostic function (6F00H to 6FFFH)
The following table lists the codes of errors, other than those detected by the self-diagnostic function of the CPU module.
Error
code
Error name
Error details and cause
Action
6F00H
Transient
execution error
• The internal buffer area for transient processing is used to
the maximum.
• Temporarily stop transient transmissions, or reduce the
frequency. Then, perform transmissions again. Or, add the
COM instruction to the programmable controller CPU and
increase the frequency. If the same error occurs again, the
possible cause is a hardware failure of the redundant
function module. Please consult your local Mitsubishi
representative.
6F01H
Transient
transmission
timeout error
• In transient transmission, timeout has occurred without
transmission completion.
• Review the network status. If the same error occurs again,
the possible cause is a hardware failure of the redundant
function module. Please consult your local Mitsubishi
representative.
6F02H
Module error
• An error has been detected in the redundant function
module.
• Please consult your local Mitsubishi representative.
6F23H
6F24H
6F25H
Module
communication
test error
• The operating status of the CPU module is in a state other
than STOP. (A test cannot be executed.)
• Change the operating status of the CPU module to STOP,
and execute a module communication test.
6F27H
Module
communication
test being
executed
• A module communication test execution request was
received during the test.
• A module communication test termination request was
received during the test.
• Since the module communication test is being executed,
execute the request again after the completion of the test.
6F28H
Module being
changed online
• A module communication test execution request was
received during online module change.
• A module communication test termination request was
received during online module change.
• Since a module is being changed online, execute the
request again after the completion of the change.
6F29H
Module
communication
test error
• A module communication test execution request was
received in the state where tracking cables are connected
incorrectly.
• Connect one end of a tracking cable to the IN connector and
the other end to the OUT connector of the test target
redundant function module, and execute the request again.
6F30H
Transient
execution error
(redundant
function module
communication
being stopped)
Data communications cannot be performed with the other
system because of any of the following reasons:
• The CPU module of the other system is powered off or in a
reset state.
• The tracking communication stops due to an error in the
CPU module of the own or other system.
• Tracking cables are disconnected or incorrectly connected,
or failed.
• The redundant function module of the own or other system is
being changed online, a module communication test is being
performed for the module, or a hardware failure has
occurred in the module.
• If a WDT error has occurred in the CPU module of the own
or other system, eliminate the error cause and then execute
the operation again.
• Check that there is no error or failure in the CPU module,
tracking cables, redundant function modules, and perform a
retry. Or, perform a retry after the online module change
processing or the module communication test ends. If the
same error code is displayed again, the possible cause is a
hardware failure of the CPU module, redundant function
module, base unit, or tracking cable. Please consult your
local Mitsubishi representative.
6F40H
Transient
execution error
The number of transient transmission requests exceeded the
upper limit of simultaneously processable requests.
• Temporarily stop transient transmissions, or reduce the
frequency. Then, perform transmissions again.
6F44H
Transient frame
error
• An invalid transient frame was received.
• Check and correct the request data (send data) on the
request source side, and perform transmissions again.
6F4AH
6F4BH
6F4CH
6F4DH
6F4EH
6F60H
Module error
• An error has been detected in the redundant function
module.
• Please consult your local Mitsubishi representative.
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......