3 MEMORY CONFIGURATION OF THE CPU MODULE
3.2 File Size Unit in Memory
3.2
File Size Unit in Memory
The minimum unit of capacity for storing a file in the memory is referred to as the file size unit (cluster size).
File size unit based on memory area
Data is written in the unit of the file size (cluster size). For example, when 464 bytes of CPU parameter is
written to the data memory on R04CPU, it is written as 1024 bytes of data because the file size unit of the data
memory is 1024 bytes.
File size unit of each SD memory card
CPU module
File size unit
Program memory
Device/label memory
Data memory
Function memory
R00CPU, R01CPU, R02CPU
4 bytes
512 bytes
1024 bytes
R04CPU, R04ENCPU
2048 bytes
R08CPU, R08ENCPU
2048 bytes
R16CPU, R16ENCPU
4096 bytes
R32CPU, R32ENCPU
8192 bytes
R120CPU, R120ENCPU
16384 bytes
R08PCPU
128 bytes
2048 bytes
R16PCPU
4096 bytes
R32PCPU
8192 bytes
R120PCPU
16384 bytes
SD memory card
File size unit
NZ1MEM-2GBSD
32K bytes
NZ1MEM-4GBSD
NZ1MEM-8GBSD
NZ1MEM-16GBSD
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......