11 DATA LOGGING FUNCTION
11.2 Data Collection Conditions
■
Specifying the monitored data
For monitored data, the following devices and labels can be specified.
*1
*1 When specifying the local device, global label, or local label, check the versions of the CPU module, engineering tool, and CPU Module
Logging Configuration Tool. (
Page 1008 Added and Enhanced Functions)
The data types that can be selected include bit/word (unsigned), word (signed), double word (unsigned), and double word
(signed).
*2 An index modified device and indirectly specified device cannot be specified.
*3 For bit devices, digit specification is not supported.
*4 For word devices, bit specification is allowed.
*5 To specify the local device, use "Program name/#Device name". (Example: "MAIN/#M1")
*6 To specify these devices with CPU Module Logging Configuration Tool, use T (contact): TS, ST (contact): STS, C (contact): CS, LT
(contact): LTS, LST (contact): LSTS, and LC (contact): LCS.
*7 The device can be collected by using the CPU module where the SFC function can be used. (
*8 A label with a name of 256 characters or less can be specified. When the local label is specified (program block name/label name), the
"program block name/" part is counted as the number of characters.
*9 Only labels in the read project of the engineering tool can be specified.
*10 Specify the label with "Program block name/Label name". (Example: "ProgPou/label_w1")
*11 Digit-specified labels cannot be specified.
*12 Bit specification is allowed.
*13 Only the contacts and current values can be specified.
*14 For the label of timer type and counter type, specify the element name. (S: contact, N: current value)
Global label example: "label_w1.S"
Local label example: "ProgPou/label_w1.S"
*15 Specify the array element. If the array element is not specified, it is handled as the start of the array ([0]). (
*16 Specify the structure member. (
Type
Device
Device
Bit device
X, Y, M
, B, SB, T (contact)
, ST (contact)
, C (contact)
, LT
(contact)
, LC (contact)
, FX, FY, Jn\X, Jn\Y, Jn\SB, Jn\B, BLn\S
Word device
T (current value)
, C (current value)
, SD, W, SW, RD, R, ZR, Z,
FD, Un\G, Jn\W, Jn\SW, U3En\G, U3En\HG
Double-word device
LT (current value)
, LC (current value)
Type
Class
Data type
Label
Global label
• VAR_GLOBAL
• VAR_GLOBAL_RETAIN
■
Primitive data type/array
• Bit
• Word (signed)
• Double word (signed)
• Word (unsigned)
• Double word (unsigned)
• Timer type
• Retentive timer type
• Counter type
• Long timer type
• Long retentive timer type
• Long counter type
■
Structure
Local label
• VAR
• VAR_RETAIN
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......