1 RUNNING A PROGRAM
1.5 Program Execution Type
Trigger setting
Use the event execution type detail setting.
[CPU Parameter]
[Program Setting]
Operating procedure
Displayed items
*1 It cannot be set in the R00CPU, R01CPU, and R02CPU.
"Program Setting" window
1.
Click "Detailed Setting" on the
"Program Setting" window.
"Detailed Setting" window
2.
Select the program name and set
the execution type to "Event".
3.
Click "Detailed Setting Information".
"Event Execution Type Detailed Setting" window
4.
Sets the trigger type to execute the
event execution type program.
Item
Description
Setting range
Default
Interruption occurrence
Sets the interrupt pointer used as the trigger.
I0 to I15, I28 to I31, I44, I45, I48
, I50 to I1023
ON of Bit Data (TRUE)
Sets the device used as the trigger.
Clear Output and Current Value of
Timer
Sets that the current values of the output (Y),
timer (T), and long timer (LT) used in this
program are cleared at the execution turn of the
event execution type program that comes after
the specified bit data is OFF.
• Do Not Clear
• Clear
Do Not Clear
Passing Time
Unit
Sets the time passed.
• When "ms" is selected: 1 to 65535ms (in units of
1ms)
• When "s" is selected: 1 to 65535s (in units of 1s)
ms
Clear Output
and Current
Value of Timer
Sets that the current values of the output (Y),
timer (T), and long timer (LT) used in this
program are cleared at the execution turn of the
event execution type program that comes after
the specified time passes.
• Do Not Clear
• Clear
Do Not Clear
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......