Appendix 6. Operation Messages on Setting and Display Unit
IV
-22
Error No.
Error message
Details
E18
PARITY V ERR
×
• A parity V error was detected during data input.
• Check the paper tape to see whether the number of characters in
the significant information section of a block is odd.
• Also check the state (cable wiring‚ noise measures‚ etc.) of the
connected equipment.
E20 OVER
RUN
ERR
×
• The control method using the DC codes‚ etc.‚ for the input/output
operation is incorrect.
• Check the settings of the input/output unit parameters‚ and the
settings on the input/output unit side‚ and reset if necessary.
E21 PROGRAM
RUNNING
×
• Deletion of a machining program was attempted during
operation.
• Search was attempted during operation.
• Change of data such as parameters was attempted during
operation.
• Start of graphic check was attempted during operation.
• When using the two systems, the program being buffer corrected
was running with the other system.
• Erasing or inputting (IC
→
NC) of a program in the IC card being
used was attempted.
• Formatting of the IC card was attempted during automatic start.
• Accessing to the host computer was attempted during automatic
operation.
E22 CODE
CHANGE
ERR
×
• There was an illegal code on the paper tape.
E24 PLC
RUN
×
• Data input/output or comparison was attempted when the PLC
was not stopped.
• Analog output adjustment was attempted when the PLC was not
stopped.
• An attempt was made to input or output language data during
PLC execution.
• When the machine manufacturer macro program memory area
was set to the FROM area, formatting of the FROM area (#1060
SETUP "20") was attempted when the PLC was not stopped,
writing of the machine manufacturer macro program was
attempted on the PROGRAM COPY screen, or input of the
macro program was attempted.
(Measures)
• Stop the PLC.
• Set the control unit rotary switch (NCSYS) to 1.
• Set the onboard file screen RUN/STOP setting to 1.
E25 DATA
MEMORY
ERR
×
• When inputting the tool offset data onto tape‚ an offset type
exceeding the specifications range was designated‚ and that
block could not be input. If the INPUT key is pressed again in the
input screen‚ the input will continue from the next block.