7. Diagnosis
7.5 Absolute Position Monitor
I
-276
#
Parameter
Explanation
Setting range (unit)
0 INIT. SET
Select the axis for which absolute position initialization is to
be performed:
0: Do not perform initialization.
1: Perform initialization.
(Note)
"0" is set when the power is turned ON again.
0/1
1 ORIGIN
This parameter is valid when the marked point alignment
method is used. Specify "1" when the machine has been
positioned to the basic point.
(Note)
This parameter is invalid for other methods.
0/1
2 ZERO
This parameter is used to determine the basic machine
coordinate system.
Specify the coordinates of the machine basic position seen
from the zero point of basic machine coordinate system or
absolute position basic point.
(Whether the machine basic position or absolute position
basic point is used is determined by data specified for "#2059
zerbas" of the setup parameter.)
Zero point of basic
machine coordinate
system
Values set to #2[ZERO]
Machine basic
position
±
99999.999 (mm)
This section explains only the ABS POSITION SET screen. For details of the actual absolute position
initialization and display contents, see Chapter IV Section 4 "Absolute Position Detection System".