6. Operation Panel Switch Functions
6.16 Deceleration Check
II
-33
6.16.3 Deceleration Check when Opposite Direction Movement is Reversed
Deceleration check cannot be designated for G1
→
G0 or G1
→
G1, but it can be designated in the
following manner only when the movement reverses to the opposite direction in successive blocks.
Deceleration check can also be executed if even one axis is moving in the opposite direction while
several axes are interpolating.
(1) Designating deceleration check for G1
→
G0 opposite direction movement reversal
If the axis movement reverse to the opposite direction in a G1 to G0 successive block, the
deceleration check for the movement in the opposite direction can be changed with the base
specification parameter G1
→
G0 deceleration check (#1502 G0Ipfg).
Same direction
Opposite direction
G0Ipfg:0
G1
G0
G1
G0
The acceleration is
excessive due to the G1
and G0 composite speed.
G0Ipfg:1
G1
G0
G1
G0
Commanded
deceleration
(2) Designating deceleration check for G1
→
G1 opposite direction movement reversal
If the axis movement reverse to the opposite direction in a G1 to G1 successive block, the
deceleration check for the movement in the opposite direction can be changed with the base
specification parameter G1
→
G1 deceleration check (#1503 G1Ipfg).
Same direction
Opposite direction
G0Ipfg:0
G1
G1
G1
G1
The acceleration is
excessive due to the G1
and G1 composite speed.
G0Ipfg:1
G1
G1
G1
G1
Commanded
deceleration
Содержание EZMotion-NC E60 Series