Pressing the menu key
I/O PARA
displays the I/O BASE PARAM screen.
There are basically two types of input/output parameters which must be set when inputting, outputting
or referring to data, or when performing tape operation. One type is the parameters related to the
input/output device. The baud rate, etc., is set according to each device. Up to five types of
input/output devices can be registered. The other type of input/output parameters is the I/O base
parameters which determine which device is connected to which channel per input/output application.
4.3.1 I/O BASE PARAM
[I/O BASE PARAM]
PARAM 2.1/7
<I/O>
# <PORT No.>
# <DEV. No.>
<DEV.NAME>
DATA IN
9001
0
9002
0
DATA OUT
9003
0
9004
0
NC RUNNING
9005
0
9006
0
MACRO PRINT
9007
0
9008
0
PLC IN/OUT
9009
0
9010
0
REMOTE PROG IN
9011
0
9012
0
RIN
EXT UNIT
9013
0
9014
0
# ( ) DATA( )
WORK PROCESS
I/O PAR
SETUP MENU
<I/O>
#
<PORT No.>
#
<DEV. No.> <DEV. NAME>
Specify the board No. to which the serial
input/output device is connected to 2.
Set the input/output device No. for
each application.
The device Nos. are 0 to 4 and
correspond to the input/output
device parameters.
The device name set in the
input/output device parameter is
also displayed for identification.
DATA IN
9001 Specify the port for inputting the data such
as machine program and parameters.
9002 Specify the No. of the device that
inputs the data.
DATA OUT
9003 Specify the port for outputting the data
such as machine program and
parameters.
9004 Specify the No. of the device that
outputs the data.
TAPE MODE
9005 Specify the input port for running with the
tape mode.
9006 Specify the No. of the device to be
run with the tape mode.
MACRO
PRINT
9007 Specify the output port for the user macro
DPRINT command.
9008 Specify the No. of the device for
the DPRINT command.
PLC IN/OUT
9009 Specify the port for inputting/outputting
various data with PLC.
9010 Specify the No. of the device for
the PLC input/output.
REMOTE
PROG IN
9011 Specify the port for inputting remote
programs.
9012 Specify the number of the device
used to input remote programs.
EXT UNIT
9013 Specify the port for communication with
an external unit.
9014 Specify the number of the unit
used for communication with an
external unit