8. Maintenance Functions
8.1 Data Input/Output Function
III
-56
(3) Example of data output operation
Confirm that the user PLC is
stopped.
Connect the output device.
Call out the data output screen.
DIAGN
IN/OUT
INPUT
OUTPUT
1) The data output screen will display.
Group output of data
ex. ALL1: Plain data
(Parameter, R register, work offset, backup data.)
Set 99 in 9 9 setting area,
and
A L L 1 in the data setting
area.
# (99) DATA ( ALL1)
Press
INPUT
key.
<OUTPUT DATA>
N3L320050L64L0L32
;
DATA
OUT
EXECUTION
# (99) data ( 10 1 )
<OUTPUT DATA>
%
DATA OUT COMPLETE
# ( ) DATA ( )
1) The output will start, and the
output data No., output data
details, and "DATA OUT
EXECUTION" message will
display.
2) The output operation will end
when the end code % (EOR) is
output, and the message "DATA
OUT COMPLETE" displays.
Содержание EZMotion-NC E60 Series
Страница 1: ......
Страница 15: ...I OPERATION SECTION ...
Страница 361: ...II MACHINE OPERATION MANUAL ...
Страница 399: ...III SETUP ...
Страница 472: ...IV APPENDIXES ...
Страница 510: ......