6. Data In/Out
6.2 DATA OUTPUT
I
-238
6.2.6 Outputting Waveform Data
Waveform data can be output.
(1) Waveform data output operation
1) Data output starts and the contents of the
output data and message "DATA OUT
EXECUTION" are displayed.
2) When tape end code % (EOR) is output, the
data output completes with message "DATA
OUT COMPLETE" displayed.
# ( 22 ) DATA ( )
<OUTPUT DATA>
%
DATA OUT COMPLETE
# ( ) DATA ( )
Press the
INPUT
key.
Set the data type to the waveform
data.
# ( 2 2 ) DATA ( )
<OUTPUT DATA>
DATA OUT EXECUTION
# ( 22 ) DATA ( )
(Note 1)
If output operations are attempted while the waveform is displayed, the operation message
"V-ANALYZER EXEC." will appear, and the waveform display data will not be output.
(Note 2)
If output operations are attempted while the Visual analyzing function is invalid, the error "E01
SETTING ERROR" will occur.
(Note 3)
The output wave form display data cannot be input.
Содержание EZMotion-NC E60 Series
Страница 1: ......
Страница 15: ...I OPERATION SECTION ...
Страница 361: ...II MACHINE OPERATION MANUAL ...
Страница 399: ...III SETUP ...
Страница 472: ...IV APPENDIXES ...
Страница 510: ......