4. Parameters (User)
4.3 I/O Parameters
I
-160
4.3.3 COMPUTER LINK PARAMETER
[COMPUTER LINK PARAMETER]
PARAM 2.7/7
#
#
#
9601 BAUD RATE
0
9611 LINK PARAM. 3
00
9621 DC1 OUT SIZE
0
9602 STOP BIT
0
9612 LINK PARAM. 4
00
9622 POLLING TIMER
0
9603 PARITY EFFECTIVE
0
9613 LINK PARAM. 5
00
9623 TRANS. WAIT TMR
0
9604 EVEN PARITY
0
9614 START CODE
0
9624 RETRY COUNTER
0
9605 CHR. LENGTH
0
9615 CTRL. CODE OUT 00
9625
9606 HAND SHAKE
0
9616 CTRL. INTERVAL
0
9626
9607 TIME-OUT SET
0
9617 WAIT TIME
0
9627
9608 DATA CODE
0
9618 PACKET LENGTH
0
9628
9609 LINK PARAM. 1
00
9619 BUFFER SIZE
0
9629
9610 LINK PARAM. 2
00
9620 START SIZE
0
9630
#( )DATA( )
WORK PROCESS
I/O PAR
SETUP MENU
# Item
Contents
Setup
range
(unit)
9601 BAUD RATE
Specify the rate at which data is transferred.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
8: 38400
9602 STOP BIT
Specify stop bit length used in start-stop mode. See
"PARITY EFFECTIVE" in #9603. The number of
characters is adjusted in output mode so that no
problems occur if the parity check is enabled.
1: 1
2: 1.5
3: 2
9603 PARITY EFFECTIVE
This parameter is set when using a parity bit
separately from the data bit.
ON
OFF
Start bit
Data bit
b1 b2 b3 b4 b5 b6
bn
1 character
Stop bit
Parity bit
Set this to match the input/output device
specifications.
0: No parity bit used
in I/O mode
1: Parity bit used in
I/O mode
9604 EVEN PARITY
Specify whether even or odd parity is used when
parity is used. This parameter is ignored when no
parity is used.
0: Odd parity
1: Even parity
9605 CHR. LENGTH
Specify data bit length.
See "PARITY EFFECTIVE" in #9603.
2: 7
3: 8
9606 HAND SHAKE
RS-232C transmission control mode
DC control mode should be set for computer line B.
0: No control
1: RTS/CTS method
2: No handshaking
3: DC control mode