2. Monitor
2.4 PROGRAM SEARCH
I
-51
2.4.4 Compare Stop
The single block stop state can be applied at a random block without turning the "SINGLE BLOCK"
switch ON.
By using compare stop, the shape machined up to the designated block can be easily compared and
machining can be resumed.
(1) Setting compare stop
O ( 1234) N ( 20) - ( 3 ) COL. ( 1) TAPE( )
Designate the program No.,
sequence No. and program No., and
set 1 in COL. ( ).
(Example)
To compare stop at
01234N20-3
O ( 1 2 3 4 ) N ( 2 0 ) - ( 3 )
COL. ( 1 ) TAPE ( )
Press the
INPUT
key.
The program No. ("MDI" for MDI),
sequence No., block No., and the
message "COLL. EXEC" will appear
at [COLLATION BLOCK]. The setting
areas will change to blanks.
To execute compare stop with an
MDI program, set 0 (zero) for the
program No.
O ( ) N ( ) - ( ) COL. ( ) TAPE ( )
[COLLATION BLOCK] COLL. EXEC
O 1234 N 20 - 3
Press the "CYCLE START" switch.
O ( ) N ( ) - ( ) COL. ( ) TAPE ( )
[COLLATION BLOCK]
O N -
1) Operation will start.
2) When the designated block is
reached, the signal block stop
state will be applied after
executing that block.
3) When the single block stop mode
is established by compare stop,
the program number, sequence
number and block number
appearing in [COLLATE BLOCK]
as well as the "COLL. EXEC"
message are cleared.
Содержание EZMotion-NC E60 Series
Страница 1: ......
Страница 15: ...I OPERATION SECTION ...
Страница 361: ...II MACHINE OPERATION MANUAL ...
Страница 399: ...III SETUP ...
Страница 472: ...IV APPENDIXES ...
Страница 510: ......