7. Diagnosis
7.4 PLC Interface Diagnosis
I
-269
(3) Forcible definition data display
(modal
type)
When forcible definition data and mode
are set, the device numbers and data are
displayed and setup data is forcibly
defined.
(Note)
To use this function during machine
running, pay extreme attention to
sequence operation.
(4) How to read device numbers and
display
data
76543210 HEX
76543210 HEX
X0000 oooooooo
00
D0005 oooooooo
00
X0008 ooooo1o1
05
o11oo1oo
64
X0010 oooooooo
00
D0006 1oooooo1
81
X0018 o1o1oooo
50
ooooo1oo
04
X0020 1o1ooo11
A3
D0007 o1oooo1o
42
X0028 1ooooo1o
82
1oooo1oo
84
X0030 oooooooo
00
D0008 oooooo1o
02
X0038 oooo11oo
0C
11oooooo
C0
Device number (bit type)
X0000
0 0 0 0 0 0
0
0
7 6 5 4 3 2 1 0
X0008
0 0 0 0 0 1
0
1
X7 X6 X5 X4 X3 X2 X1 X0
X0010
0 0 0 0 0 0
0
0
XF XE XD XC XB XA X9 X8
X17 X16 X15 X14 X13 X12 X11 X10
The device number are assigned
bitwise.
State display of signal
corresponding to each
device number (1 or 0)
2-byte data
corresponding to each
device number
Device number (2-byte type)
D0005
0 0 0 0 0 0
0
0
7 6 5 4 3 2 1 0
High-order data
0 1 1 0 0 1
0
0
This data indicates decimal number 100.
Low-order data
<SET
DATA>
X0008=0001
Y0015=0000
X000A=0001
D0005=0064
Up to four devices that have been
forcibly defined are displayed.